Showing specs for all NA & NB Miatas

Intake-air sensor No.2 resistance and references (2004–2005 turbo)

Disconnected sensor A–B: approximately 33 kΩ at 77 °F (25 °C); approximately 3.5 kΩ at 185 °F (85 °C). Reference table at −20/0/20/40/140 °F (60 °C; −4/32/68/104/): approximately 357/112/41/17/8 kΩ and 4.6/4.0/3.0/2.0/1.2 V, respectively.Disconnected sensor A–B: approximately 33 kΩ at 25°C {77°F}; approximately 3.5 kΩ at 85°C {185°F}. Reference table at −20/0/20/40/60°C {−4/32/68/104/140°F}: approximately 357/112/41/17/8 kΩ and 4.6/4.0/3.0/2.0/1.2 V, respectively.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Follow the troubleshooting flowchart before inspection. Disconnect the turbo engine’s IAT No.2 connector and use an ohmmeter across its two component contacts A and B at the stated ambient temperatures; replace if incorrect. If the component passes but the monitor reference is wrong, follow the separate PCM-disconnected harness diagnosis. The additional resistance/voltage table is explicitly approximate reference data; it supplies no acceptance tolerances or standalone powered-probe procedure. Keep this sensor distinct from IAT No.1 and the ECT thermistor; do not interpolate limits from the reference graph.

Applies to
  • NB 2004–2005 (BP-Z3-TURBO, 6MT) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
  • Verified in: 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)

Sources (1)

View 1 source citations
  • 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page IAT Sensor No.2 Inspection [BP WITH TC] (PDF pp.981–983) · Printed value & notes
    Page IAT Sensor No.2 Inspection [BP WITH TC] (PDF pp.981–983)
    Printed: “Disconnect the IAT sensor No.2 connector. Verify that the resistance between terminals A and B is within the specification. Ambient temperature (°C {°F}) Resistance (kilohm) 25 {77} Approx. 33 85 {185} Approx. 3.5 IAT sensor characteristics table (reference) Ambient temperature (°C {°F}) -20 {-4} 0 {32} 20 {68} 40 {104} 60 {140} Resistance (kilohm) Approx. 357 Approx. 112 Approx. 41 Approx. 17 Approx. 8 Voltage (V) Approx. 4.6 Approx. 4.0 Approx. 3.0 Approx. 2.0 Approx. 1.2”