Immobilizer antenna-coil circuits in LOCK — non-turbo (2001–2005)
Ignition LOCK, D coil supply and F key-ID input: each below 0.1 V. Ignition ON: source gives no measurable voltage acceptance.Ignition LOCK, D coil supply and F key-ID input: each below 0.1 V. Ignition ON: source gives no measurable voltage acceptance.
On the original immobilizer harness connector, view from the wire-entry side with the broad crossed central key at the top. Upper contacts left to right are M, K, then the wide central key, then E, C, A. Lower contacts left to right are N, L, J, H, F, D, B. Keep the unit plugged in for voltage checks to ground; disconnect its connector before harness-ground continuity at C. B+ means battery voltage. These checks require the original corresponding equipment. Check the two coil circuits only against the stated LOCK-position voltage reference. Both ON rows say “Can not be measured”; do not substitute a DC voltage or infer an open circuit from that wording. Inspect the antenna coil and related harness if the LOCK reference fails.
- NB 2003–2005 (BP-Z3)
- NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
- Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition); 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)
Sources (4)
View 4 source citations
- Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
Page 09–14–19 (PDF p. 890) · Printed value & notes
Part no. 1719-1U-01GPage 09–14–19 (PDF p. 890)Printed: “D Power supply to coil Coil IG SW LOCK position Below 0.1 IG SW ON position Can not be measured F Key ID number input Coil IG SW LOCK position Below 0.1 IG SW ON position Can not be measured”Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned. - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Immobilizer Unit Inspection (PDF pp. 1950, 1951) · Printed value & notes
Page Immobilizer Unit Inspection (PDF pp. 1950, 1951)Printed: “D Power supply to coil Coil IG SW LOCK position Below 0.1 IG SW ON position Can not be measured F Key ID number input Coil IG SW LOCK position Below 0.1 IG SW ON position Can not be measured” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Immobilizer Unit Inspection (PDF pp. 1945, 1946) · Printed value & notes
Page Immobilizer Unit Inspection (PDF pp. 1945, 1946)Printed: “D Power supply to coil Coil IG SW LOCK position Below 0.1 IG SW ON position Can not be measured F Key ID number input Coil IG SW LOCK position Below 0.1 IG SW ON position Can not be measured” - 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page PDF pp. 2077–2078 · Printed value & notes
Page PDF pp. 2077–2078Printed: “D Power supply to coil Coil IG SW LOCK position Below 0.1 IG SW ON position Can not be measured F Key ID number input Coil IG SW LOCK position Below 0.1 IG SW ON position Can not be measured”
Related service specs
- Immobilizer PCM communication voltage reference — non-turbo (2001–2004)
- Immobilizer security-light inactive output — non-turbo (2001–2005)
- Keyless module door-open input — non-turbo (2001–2004)
- Keyless module panic horn and headlight outputs — non-turbo (2001–2004)
- Keyless module hazard acknowledgement output — non-turbo (2001–2004)
- Keyless module trunk-release relay output — non-turbo (2001–2004)
- Keyless module driver-door lock/unlock output — non-turbo (2001–2005)
- Door-lock module supply and grounds — non-turbo (2001–2005)