Oxygen-sensor voltage response — early NB2
Sudden engine-speed increase: 0.5–1.0 V; sudden decrease: 0–0.5 V at disconnected sensor signal terminal A to ground.Sudden engine-speed increase: 0.5–1.0 V; sudden decrease: 0–0.5 V at disconnected sensor signal terminal A to ground.
Perform only when directed by factory diagnosis. Warm the engine and idle it, disconnect the oxygen-sensor connector, and connect a voltmeter from sensor-side signal terminal A to ground. Looking into the sensor’s connector terminal face with the latch uppermost, the front sensor has A/C on the upper row and B/D below; the rear has C/A above D/B. Run at 3,000 rpm until the meter indicates 0–1.0 V, then observe voltage while suddenly increasing and decreasing speed several times. Compare the respective ranges and reconnect after testing. If response passes but the scan PID does not, inspect the circuit; otherwise replace the sensor. This is the signal-voltage test, separate from the C–D heater-resistance check.
- NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
- Verified in: Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)
Sources (1)
View 1 source citations
- Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
Page 01–40–31 (PDF p. 403) · Printed value & notes
Part no. 1719-1U-01GPage 01–40–31 (PDF p. 403)Printed: “Perform the following test only when directed. Warm up the engine and idle it. Disconnect the HO2S connector. Connect a voltmeter between the HO2S connector terminal A and a GND. Run the engine at 3,000 rpm until the voltmeter indicates 0—1.0 V. Engine condition Increased Decreased Voltage (V) 0.5—1.0 0—0.5”Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned.