PCM rear oxygen-sensor and heater scan references (2004)
O2S12: ignition ON, 0–1.0 V; warm idle, 0–1.0 V; cold idle, 0–0.5 V; acceleration, 0.5–1.0 V; deceleration, 0–0.5 V. HTR12: coolant above 158 °F (70 °C), ON; below 158 °F (70 °C), OFF.O2S12: ignition ON, 0–1.0 V; warm idle, 0–1.0 V; cold idle, 0–0.5 V; acceleration, 0.5–1.0 V; deceleration, 0–0.5 V. HTR12: coolant above 70°C {158°F}, ON; below 70°C {158°F}, OFF.
Connect WDS or equivalent to DLC-2, turn the ignition ON and read the named PID under each stated condition. These are PCM scan-tool references, not instructions to probe connector pins. If the reference is not met, follow the factory action column and the appropriate component diagnosis. Read the connected PCM O2S12 and HTR12 PIDs. No heater state is specified at exactly70°C. Follow the HO2S or heater diagnosis if incorrect. These are scan references and do not resolve the separate held disconnected-sensor voltage test or authorize terminal probing.
- NB 2004 (BP-Z3)
- Verified in: 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)
Sources (3)
View 3 source citations
- 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page PCM Inspection — Using SST (WDS or Equivalent), procedure (PDF p.891) · Printed value & notes
Page PCM Inspection — Using SST (WDS or Equivalent), procedure (PDF p.891)Printed: “Connect the WDS or equivalent to the DLC-2. Turn the ignition switch to ON. Measure the value. If value is not within the specification, follow the instructions in ACTION column.” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page PCM Inspection — scan reference table (PDF p.895) · Printed value & notes
Page PCM Inspection — scan reference table (PDF p.895)Printed: “O2S12 (Heated oxygen sensor (Rear)) Ignition switch ON: 0—1.0 V Idle (After warm up): 0—1.0 V Idle (Engine cold): 0—0.5 V Accelerate: 0.5—1.0 V Decelerate: 0—0.5 V” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page PCM Inspection — heater scan reference table (PDF p.894) · Printed value & notes
Page PCM Inspection — heater scan reference table (PDF p.894)Printed: “HTR12 ECT above 70°C {158°F}: ON ECT below 70°C {158°F}: OFF”
Related service specs
- PCM injector-duration scan reference (2004)
- PCM intake-air-temperature scan reference (2004)
- PCM knock-retard scan reference (2004)
- PCM long-term fuel-trim scan reference (2004)
- PCM MAF voltage scan reference (2004)
- PCM front oxygen-sensor and heater scan references (2004)
- PCM EGR step-position scan reference (2004)
- PCM short-term fuel-trim scan reference (2004)