Windshield wiper motor parked continuity (2004–2005)
With the motor parked and then isolated: A, B, C and motor-body ground have continuity.With the motor parked and then isolated: A, B, C and motor-body ground have continuity.
Look directly into the isolated motor-side terminal face with its locating tab above: top row C (left), A (right); bottom row D (left), B (right). Reconnect the normal vehicle harness, turn ignition ON and run the wipers. Turn the wiper switch OFF while leaving ignition ON, and verify the blades return to their parked position. Disconnect the motor connector before metering the stated group. These paths include motor windings; no zero-ohm acceptance is inferred. The parked table supplies no D acceptance. The actual 2004 parked table is an image on the third PDF page and was checked visually; its absence from extracted text is not a missing factory acceptance.
- NB 2005 (BP-Z3/BP-Z3-TURBO)
- NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
- Verified in: 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)
Sources (1)
View 1 source citations
- 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Windshield Wiper Motor Inspection (PDF pp.2262–2263) · Printed value & notes
Page Windshield Wiper Motor Inspection (PDF pp.2262–2263)Printed: “Turn the windshield wiper switch off while the windshield wipers are operating. Verify that the windshield wipers stop in the park position. Disconnect the windshield wiper motor connector. Park position A B C Body GND”
Related service specs
- Airbag service handling and inspection limits (2004–2005)
- New SAS module authorization and lamp check (2004–2005)
- Airbag warning lamp check after service (2004–2005)
- PAD switch isolated continuity and bulb paths (2004–2005)
- Seat-belt buckle switch continuity (2004–2005)
- Seat-belt emergency-locking retractor check (2004–2005)
- Removed clock-spring conductor continuity (2004–2005)
- Fuel-filler lid panel gap and flushness (2004–2005)