Showing specs for all NA & NB Miatas

Airbag three-flash diagnostic battery-voltage check (1990–1991)

For the original SRS three-flash diagnostic: battery voltage greater than 9 V permits continuing to fuse checks; below 9 V calls for charging by the factory battery procedure.For the original SRS three-flash diagnostic: battery voltage greater than 9 V permits continuing to fuse checks; below 9 V calls for charging by the factory battery procedure.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Measure at the vehicle battery terminals at the start of the three-flash power-source diagnostic, before disconnecting SRS connectors. This is a diagnostic entry threshold, not a normal battery state-of-charge specification. The printed table assigns no branch to exactly 9 V. The next checks concern separate INJ 30 A and AIR BAG 10 A main-block fuses and AIR BAG 15 A and ENGINE 15 A cabin fuses. Subsequent SRS connector work requires the complete factory disabling procedure; this battery measurement does not authorize probing the inflator.

Applies to
  • NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
  • Verified in: 1990 Mazda MX-5 Miata Workshop Manual