Showing specs for all NA & NB Miatas

Inhibitor switch continuity (1992–1993 4AT)

P and N: terminals 1–2 continuous. R: terminals 3–4 continuous. D, 1 and 2: neither listed pair continuous.P and N: terminals 1–2 continuous. R: terminals 3–4 continuous. D, 1 and 2: neither listed pair continuous.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Test the disconnected, unpowered inhibitor switch with the vehicle safely supported and control linkage disconnected from the manual shaft. Use the factory-numbered switch terminals: 1/2 are the starter-inhibit pair and 3/4 the reverse-lamp pair. Move the shaft to each indicated range and measure the listed pairs with an ohmmeter. In the installed functional check, the starter must operate only in P/N with ignition at START and reverse lamps must illuminate in R with ignition ON. Adjust the switch alignment first if incorrect and replace if continuity remains incorrect after adjustment. Do not apply battery voltage to an ohmmeter test.

Applies to
  • NA 1992–1993 (B6, 4AT) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
  • Verified in: 1992 Mazda MX-5 Miata Workshop Manual