Showing specs for all NA & NB Miatas

Automatic second-band servo air operation check (1992–1993)

Air pressure maximum 57 psi (392 kPa; 4.0 kg/cm²); verify that the piston stem moves toward the brake band. Apply air for no more than three seconds during the final assembled operation check.Air pressure maximum 392 kPa (4.0 kg/cm², 57 psi); verify that the piston stem moves toward the brake band. Apply air for no more than three seconds during the final assembled operation check.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Apply compressed air through the engage passage identified in the factory second-band servo figure; distinguish it from the separately labeled release passage. If the piston stem does not move toward the brake band, inspect for seal-ring or oil-seal damage and piston sticking during assembly and replace parts as necessary. This is the second-band servo preinspection, separate from the OD servo and band-adjustment torque/backoff procedure. After the second-band seating, three-turn backoff and locknut adjustment, check both engage and release passages identified as A and B in the final-assembly figure; apply air for no more than three seconds.

Applies to
  • NA 1992–1993 (B6, 4AT) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
  • Verified in: 1992 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • 1992 Mazda MX-5 Miata Workshop ManualTier 1
    Page K–70 (PDF p. 462) · Printed value & notes
    Part no. 1271-10-91G (9999-95-0428-92)
    Page K–70 (PDF p. 462)
    Printed: “2ND band servo operation Apply compressed air through the oil passage shown. Air pressure: 392 kPa (4.0 kg/cm², 57 psi) max. Verify that the piston stem moves toward the brake band. RELEASE ENGAGE”
  • 1992 Mazda MX-5 Miata Workshop ManualTier 1
    Page K–123 (PDF p. 515) · Printed value & notes
    Part no. 1271-10-91G (9999-95-0428-92)
    Page K–123 (PDF p. 515)
    Printed: “Apply air for no more than three (3) seconds. Air pressure: 392 kPa (4.0 kg/cm², 57 psi) max.”