Showing specs for all NA & NB Miatas

Automatic torque converter seating depth (1992–1993)

Distance A: 0.89 in (22.5 mm) minimum.Distance A: 22.5 mm (0.89 in) minimum.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

After installing the torque converter, verify its axial setback into the converter housing before removing the transmission from the stand. Measure parallel to the shaft axis between the converter housing engine-mating flange plane and the converter engine-facing drive-plate mounting surface using the factory figure endpoints. The converter mounting surface must be recessed by at least the printed minimum. This is a seating check, not a bolt torque or permission to pull the converter into place with fasteners.

Applies to
  • NA 1992–1993 (B6, 4AT) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
  • Verified in: 1992 Mazda MX-5 Miata Workshop Manual

Sources (1)

View 1 source citations
  • 1992 Mazda MX-5 Miata Workshop ManualTier 1
    Page K–126 (PDF p. 518) · Printed value & notes
    Part no. 1271-10-91G (9999-95-0428-92)
    Page K–126 (PDF p. 518)
    Printed: “Ensure that the torque converter is installed correctly by measuring distance (A) between the end of the torque con- verter and the end of the converter housing. “A”: 22.5mm (0.89 in) min.”