Convertible-top frame and cable rivet removal drill diameter (1990–1991)
Removal drill diameter: φ0.16 in (4.0 mm; φ).Removal drill diameter: φ4.0 mm (φ0.16 in).
For the original convertible-top fabric/frame disassembly: the link-assembly rivets, end-plate rivets and front cable attachment rivets identified in the factory procedure. Remove the top from the body and set it upside down on a clean surface before removing the set plate, weatherstrips and retainers. Drill the link and end-plate rivets, remove end-plate screws and plates, fold the top as directed, and detach the fabric from the frame and front header. Release the rear cable screws, unfold the top, then drill the front cable attachment rivets. Follow the remaining protected-screwdriver bow-retainer and cable-guide steps without damaging fabric or rear window. This is a removal drill size; it does not specify the installation rivet material, grip length or diameter.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page S–63 (PDF p.570) · Printed value & notes
Part no. 1193-10-89CPage S–63 (PDF p.570)Printed: “Drill size: φ4.0mm (φ0.16 in)”Page S–64 (PDF p.571) · Printed value & notes
Part no. 1193-10-89CPage S–64 (PDF p.571)Printed: “Drill size: φ4.0mm (φ0.16 in)”
Related service specs
- Original tachometer winding resistance (2005, non-turbo)
- Original fuel gauge winding resistance (2005, non-turbo)
- Original water temperature gauge winding resistance (2005, non-turbo)
- Original oil pressure gauge winding resistance (2005, non-turbo)
- Door-lock removal glass position and screen preservation (1990–1991)
- Power-window main-switch supply and harness ground checks (1990–1991)
- Factory windshield and hardtop rear-glass repair-seal hardening times (1990–1991)
- Wiper switch and motor harness voltage checks (1990–1991 USA)