Factory S46A24LS battery charging-current limits (1990–1993)
Slow charge: under 3 A; quick charge: maximum 20 A.Slow charge: under 3 A; quick charge: maximum 20 A.
These limits apply to the original S46A24LS battery with its vent manifold, not an unspecified replacement battery. Stop the engine and switch off accessories. Remove the cover and disconnect the battery cables, negative first and reconnect it last. Do not remove vent caps; follow the charger instructions to prevent overcharging. Measure battery voltage before selecting charging current and duration. The factory uses a voltage-dependent current/time chart, so the maximum current is not permission to charge for an arbitrary duration; no single charging time is specified by this record.
- NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page G–9 (PDF p. 293) · Printed value & notes
Part no. 1193-10-89CPage G–9 (PDF p. 293)Printed: “Battery / Slow charge (A) / Quick charge (A) S46A24L(S) / Under 3 / Max. 20”Visually checked against the original 1990 factory page, including printed units and component/test context.- 1992 Mazda MX-5 Miata Workshop ManualTier 1
Page G–9 (PDF p. 305) · Printed value & notes
Part no. 1271-10-91G (9999-95-0428-92)Page G–9 (PDF p. 305)Printed: “Battery S46A24LS Slow charge (A) Under 3 Quick charge (A) Max. 20”
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)
- BTN fuse rating — main fuse block (1990–1993)