Updated specs are available.
Ignition coil case insulation resistance (1990–1993)
This spec doesn't apply to the car you selected.
Not yet checked against the factory manual for your car's year. It's verified in the 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual; later manuals may differ.
10 MΩ minimum, using a 500 V megger tester10 MΩ minimum, using a 500 V megger tester
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure
Isolate the ignition coil from vehicle wiring before measuring between its primary terminal and case. This factory test specifies a 500 V insulation tester; it is not the ordinary ohmmeter winding-resistance check.
Applies to
- NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page G–21 (PDF p. 305) · Printed value & notes
Part no. 1193-10-89CPage G–21 (PDF p. 305)Printed: “Use a 500V megger tester to measure the insulation resistance between the primary terminal and the coil case. Resistance : 10 MΩ min.”Visually checked against the original 1990 factory page, including printed units and component/test context.- 1992 Mazda MX-5 Miata Workshop ManualTier 1
Page G–19 (PDF p. 315) · Printed value & notes
Part no. 1271-10-91G (9999-95-0428-92)Page G–19 (PDF p. 315)Printed: “Use a 500V megger tester to measure the insulation resistance between the primary terminal and the coil case. Resistance : 10 MΩ min.”
Related service specs
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)
- BTN fuse rating — main fuse block (1990–1993)