Showing specs for all NA & NB Miatas

Fuel pump isolated hold pressure (1999–2000)

More than 50 psi (340 kPa; 3.5 kgf/cm²), five minutes after pump shutdown.More than 340 kPa (3.5 kgf/cm², 50 psi), five minutes after pump shutdown.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Before opening the fuel system, follow 01–14–1: keep ignition sources away, remove the filler cap to release tank pressure, disconnect the fuel-pump relay above the accelerator pedal, run the engine until it stalls, crank several times, turn ignition OFF and reinstall the relay. Disconnect the negative battery cable before connecting the gauge. Use SST 49 N013 1A0 at the high-pressure fuel-filter outlet with its outlet plugged by the lever as illustrated. Support the vehicle on safety stands; keep the disconnected connector clean and observe retainer replacement requirements. Fit the SST securely, put its drain hose in a container, reconnect the battery and jumper only the specified DLC F/P and GND terminals. Keep the engine stopped. Turn ignition ON for ten seconds, turn OFF, then read after five minutes. Remove the jumper. Replace the pump if incorrect. This blocked-outlet pump retention test is separate from the regulator/system hold test. Restore the fuel connections using the factory quick-release procedure, verify that they click and remain secure when pulled, and carry out 01–14–2 after-repair leakage inspection: engine stopped, DLC F/P to GND, ignition ON to operate the pump for at least five minutes, checking for leakage. Repair leaks and repeat the check.

Applies to
  • NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • Page 01–14–1–2, 01–14–9–10 (PDF pp. 234–235, 242–243) · Printed value & notes
    Page 01–14–1–2, 01–14–9–10 (PDF pp. 234–235, 242–243)
    Printed: “Turn the ignition switch to ON for 10 seconds to operate the fuel pump. Turn the ignition switch off. Measure the fuel pump hold pressure after 5 minutes. Fuel pump hold pressure More than 340 kPa {3.5 kgf/cm², 50 psi}”
  • Page 01–50–2 (PDF p. 313) · Printed value & notes
    Page 01–50–2 (PDF p. 313)
    Printed: “Fuel pump hold pressure (kPa {kgf/cm², psi}) More than 340 {3.5, 50}”