Showing specs for all NA & NB Miatas

Interior lamp supply, ground and door-mode voltage checks (1990–1991)

Lamp control ON: blue/red (L/R) supply 12 V; black (B) ground 0 V. For a dark lamp in DOOR mode with both doors open: red/white (R/W) at 12 V leads to door-switch checks; 0 V leads to lamp-assembly inspection/replacement.Lamp control ON: blue/red (L/R) supply 12 V; black (B) ground 0 V. For a dark lamp in DOOR mode with both doors open: red/white (R/W) at 12 V leads to door-switch checks; 0 V leads to lamp-assembly inspection/replacement.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Check the ROOM 10 A fuse and each bulb first. Measure each identified wire at the connected interior-lamp connector relative to body ground. In manual ON mode, a missing blue/red feed calls for supply-circuit inspection; 12 V on black calls for ground-circuit repair. With supply and ground correct, the source directs replacement of an inoperative lamp assembly. The separate DOOR-mode branch localizes a dark-lamp fault: its 12 V and 0 V readings route the next checks, and are not both healthy acceptance values. Perform door-switch continuity separately with its connector disconnected. The factory prints nominal 12 V without a numerical tolerance.

Applies to
  • NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
  • Verified in: 1990 Mazda MX-5 Miata Workshop Manual