Original speedometer winding resistance — non-turbo (2001–2004)
136–184 Ω for each of the two diagonal contact pairs.136–184 Ω for each of the two diagonal contact pairs.
Remove the speedometer from the instrument cluster. Look directly at the exposed rear contacts, orienting the projecting mounting ears at the top and lower left. Four contacts surround the round center in two vertical pairs. Measure upper-left to lower-right (factory A–B), then lower-left to upper-right (C–D); each diagonal pair must be 136–184 Ω. These are two separate readings, not one measurement across adjacent contacts. Use an ohmmeter on the removed gauge and replace it if not as specified. This is a winding-resistance check, not a powered accuracy or calibration test.
- NB 2003–2004 (BP-Z3)
- NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
- Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)
Sources (3)
View 3 source citations
- Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
Page 09–22–3 (PDF p. 993) · Printed value & notes
Part no. 1719-1U-01GPage 09–22–3 (PDF p. 993)Printed: “R: 136—184 Ω”Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned. - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Instrument Cluster Inspection (PDF p. 2246) · Printed value & notes
Page Instrument Cluster Inspection (PDF p. 2246)Printed: “Step 1 A B : R Step 2 C D : R R: 136—184 Ω” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Instrument Cluster Inspection (PDF p. 2256) · Printed value & notes
Page Instrument Cluster Inspection (PDF p. 2256)Printed: “Step 1 A B : R Step 2 C D : R R: 136—184 Ω”
Related service specs
- Immobilizer PCM communication voltage reference — non-turbo (2001–2004)
- Immobilizer antenna-coil circuits in LOCK — non-turbo (2001–2005)
- Immobilizer security-light inactive output — non-turbo (2001–2005)
- Keyless module door-open input — non-turbo (2001–2004)
- Keyless module panic horn and headlight outputs — non-turbo (2001–2004)
- Keyless module hazard acknowledgement output — non-turbo (2001–2004)
- Keyless module trunk-release relay output — non-turbo (2001–2004)
- Keyless module driver-door lock/unlock output — non-turbo (2001–2005)