Showing specs for all NA & NB Miatas

Purge-control solenoid winding resistance (1990–1993)

23–27 Ω at 68 °F (20 °C)23–27 Ω at 20°C (68°F)

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Resistance of the original purge-control solenoid winding at the stated temperature. This is separate from the ISC winding and circuit-opening relay. The technical table provides no terminal-face diagram or powered flow test; do not infer pin positions or apply resistance measurements to an energized circuit.

Applies to
  • NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
  • NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
  • Verified in: 1990 Mazda MX-5 Miata Workshop Manual; 1992 Mazda MX-5 Miata Workshop Manual

Sources (5)

View 5 source citations
  • Page F–9 (PDF p. 153) · Printed value & notes
    Part no. 1193-10-89C
    Page F–9 (PDF p. 153)
    Printed: “Solenoid valve (Purge control) Solenoid resistance Ω 23—27 (at 20°C, 68°F)”
  • Page TD–6 (PDF p. 792) · Printed value & notes
    Part no. 1193-10-89C
    Page TD–6 (PDF p. 792)
    Printed: “Solenoid valve (Purge control) Solenoid resistance Ω 23—27 (at 20°C, 68°F)”
    Visually checked against the original 1990 factory page, including printed units and component/test context.
  • 1992 Mazda MX-5 Miata Workshop ManualTier 1
    Page TD–6 (PDF p. 1048) · Printed value & notes
    Part no. 1271-10-91G (9999-95-0428-92)
    Page TD–6 (PDF p. 1048)
    Printed: “Solenoid valve (Purge control) Solenoid resistance Ω 23—27 (at 20°C, 68°F)”
  • 1992 Mazda MX-5 Miata Workshop ManualTier 1
    Page F–9 (PDF p. 163) · Printed value & notes
    Part no. 1271-10-91G (9999-95-0428-92)
    Page F–9 (PDF p. 163)
    Printed: “Solenoid valve (Purge control) Solenoid resistance Ω 23—27 (at 20°C, 68°F)”
  • 1992 Mazda MX-5 Miata Workshop ManualTier 1
    Page F–87 (PDF p.241) · Printed value & notes
    Part no. 1271-10-91G (9999-95-0428-92)
    Page F–87 (PDF p.241)
    Printed: “Resistance: 25 ± 2Ω”