Turn/hazard flasher polarized continuity test (1990–1991)

At the factory ×1000 Ω meter range, continuity from positive lead a to negative e/f; from positive c or h to every other populated contact. All other ordered pairs: no continuity.At the factory ×1000 Ω meter range, continuity from positive lead a to negative e/f; from positive c or h to every other populated contact. All other ordered pairs: no continuity.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Disconnect the original turn/hazard flasher unit and use the factory ohmmeter test at the ×1000 Ω range. View its component terminal face with the raised center key at the top and the unoccupied cavity at lower right. Upper contacts from left to right are g, e, c, a; lower contacts from left to right are h, f, d, then the unoccupied cavity. Preserve the table’s positive/negative meter-lead assignment: place positive on a and negative on e or f for continuity; positive on c or h gives continuity to each of the other six populated contacts. Every other ordered pair among the seven contacts has no continuity. This is a directional component test, with no numerical resistance acceptance printed; the range marking is a meter setting. Replace the unit if not as specified.

Applies to
  • NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
  • Verified in: 1990 Mazda MX-5 Miata Workshop Manual

Sources (4)

View 4 source citations
  • Page T–16 (PDF p.598) · Printed value & notes
    Part no. 1193-10-89C
    Page T–16 (PDF p.598)
    Printed: “Set the ohmmeter to ×1000Ω range. Terminal + − Continuity a — c X a — d X a — e ○ a — f ○ a — g X a — h X c — a ○ c — d ○ c — e ○ c — f ○ c — g ○ c — h ○ d — a X d — c X d — e X d — f X d — g X d — h X e — a X e — c X e — d X e — f X e — g X e — h X f — a X f — c X f — d X f — e X f — g X f — h X g — a X g — c X g — d X g — e X g — f X g — h X h — a ○ h — c ○ h — d ○ h — e ○ h — f ○ h — g ○ ○: Indicates continuity X: No continuity”
  • Page T–70 (PDF p.652) · Printed value & notes
    Part no. 1193-10-89C
    Page T–70 (PDF p.652)
    Printed: “Set the ohmmeter to ×1000Ω range. Terminal + − Continuity a — c X a — d X a — e ○ a — f ○ a — g X a — h X c — a ○ c — d ○ c — e ○ c — f ○ c — g ○ c — h ○ d — a X d — c X d — e X d — f X d — g X d — h X e — a X e — c X e — d X e — f X e — g X e — h X f — a X f — c X f — d X f — e X f — g X f — h X g — a X g — c X g — d X g — e X g — f X g — h X h — a ○ h — c ○ h — d ○ h — e ○ h — f ○ h — g ○ ○: Indicates continuity X: No continuity”
  • Page T–63 (PDF p.645) · Printed value & notes
    Part no. 1193-10-89C
    Page T–63 (PDF p.645)
    Printed: “Set the ohmmeter to ×1000Ω range. Terminal + − Continuity a — c X a — d X a — e ○ a — f ○ a — g X a — h X c — a ○ c — d ○ c — e ○ c — f ○ c — g ○ c — h ○ d — a X d — c X d — e X d — f X d — g X d — h X e — a X e — c X e — d X e — f X e — g X e — h X f — a X f — c X f — d X f — e X f — g X f — h X g — a X g — c X g — d X g — e X g — f X g — h X h — a ○ h — c ○ h — d ○ h — e ○ h — f ○ h — g ○ ○: Indicates continuity X: No continuity”
  • Page T–65 (PDF p.647) · Printed value & notes
    Part no. 1193-10-89C
    Page T–65 (PDF p.647)
    Printed: “Set the ohmmeter to ×1000Ω range. Terminal + − Continuity a — c X a — d X a — e ○ a — f ○ a — g X a — h X c — a ○ c — d ○ c — e ○ c — f ○ c — g ○ c — h ○ d — a X d — c X d — e X d — f X d — g X d — h X e — a X e — c X e — d X e — f X e — g X e — h X f — a X f — c X f — d X f — e X f — g X f — h X g — a X g — c X g — d X g — e X g — f X g — h X h — a ○ h — c ○ h — d ○ h — e ○ h — f ○ h — g ○ ○: Indicates continuity X: No continuity”