Water-temperature gauge installed resistance-substitution check (1990–1991, U.S.)

SST resistance: 183 Ω at the low reference mark; 20 Ω at the high reference mark. Check each for at least two minutes; allowable indication error is twice the needle width.SST resistance: 183 Ω at the low reference mark; 20 Ω at the high reference mark. Check each for at least two minutes; allowable indication error is twice the needle width.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

For the original U.S. instrument-cluster water-temperature gauge that does not operate, use factory checker SST 49 0839 285. Disconnect the connector from the gauge water thermosensor. Connect the checker red lead to the disconnected vehicle-harness contact and its black lead to body ground. Set the checker to each resistance, turn the ignition ON and compare the needle with the low and high end reference marks of the factory gauge arc near C and H. Allow at least two minutes for each reading. These are gauge indication marks, without an assigned coolant temperature. If both readings are correct, the factory diagnostic branch replaces the water thermosensor. Otherwise continue with the full factory cluster and harness diagnosis before replacing a component.

Applies to
  • NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
  • Verified in: 1990 Mazda MX-5 Miata Workshop Manual

Sources (1)

View 1 source citations
  • Page T–30 (PDF p.612) · Printed value & notes
    Part no. 1193-10-89C
    Page T–30 (PDF p.612)
    Printed: “Disconnect the connector from the water thermosensor. Connect the red lead of the SST to the connector, and the black lead to a body ground. 183Ω 20Ω Turn the ignition switch ON, and check that the needle indicates the correct values. Continue the above checks for at the least two minutes each to correctly judge the condition. The allowable indication error is twice the width of the needle.”