A/C evacuation and vacuum retention check (2001–2004)
Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.
Original R-134a system. Use R-134a recovery/recycling/recharging equipment and recover refrigerant before opening the system. Install the manifold gauge set with both side valves closed before connecting the high/low service couplers. Connect the vacuum pump to the manifold center joint, and the tap-pin side of the charging hose to its air-purge valve. Connect the tank to the charging hose and place it on a scale, keeping the tank supply closed for evacuation. Open the manifold valves and operate the vacuum pump. After the stated time and gauge readings, close each manifold valve before stopping the pump. Wait about five minutes and inspect the low-side reading. If it changes, check for leaks and repeat evacuation. If unchanged, proceed to the separate preliminary refrigerant leak check. These are signed manifold gauge readings, not absolute pressure.
- NB 2003 (BP-Z3)
- NB 2004 (BP-Z3)
- NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
- Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)
Sources (5)
View 5 source citations
- Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
Page 07–10–4 (PDF p. 741) · Printed value & notes
Part no. 1719-1U-01GPage 07–10–4 (PDF p. 741)Printed: “Start the vacuum pump and let it operate for 15 minutes. Verify that the high- and low-pressure side readings of the manifold gauge are at –101 kPa {–760 mmHg, –29.9 inHg}. Close each valve of the manifold gauge. Stop the vacuum pump and wait for about 5 minutes. If the reading has changed, check for leaks and then repeat from step 7.”Visually checked against the original page. Early-NB2 mechanical use authorized by owner; exact full-document edition and market remain unconfirmed. - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Refrigerant charging (PDF p. 1613) · Printed value & notes
Page Refrigerant charging (PDF p. 1613)Printed: “Start the vacuum pump and let it operate for 15 minutes.” - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Refrigerant charging (PDF p. 1614) · Printed value & notes
Page Refrigerant charging (PDF p. 1614)Printed: “Verify that the high and low-pressure side readings of the manifold gauge are at –101 kPa {–760 mmHg, –29.9 inHg}. Close each valve of the manifold gauge. Stop the vacuum pump and wait for about 5 minutes.” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Refrigerant charging (PDF p. 1609) · Printed value & notes
Page Refrigerant charging (PDF p. 1609)Printed: “Start the vacuum pump and let it operate for 15 minutes.” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Refrigerant charging (PDF p. 1610) · Printed value & notes
Page Refrigerant charging (PDF p. 1610)Printed: “Verify that the high and low-pressure side readings of the manifold gauge are at –101 kPa {–760 mmHg, –29.9 inHg}. Close each valve of the manifold gauge. Stop the vacuum pump and wait for about 5 minutes.”
Related service specs
- Heater blower-speed switch continuity (1990–1993)
- Heater blower-motor supply voltage (1992–1993)
- Heater blower-resistor connected voltage checks (1992–1993)
- Heater blower-switch connected voltage checks (1992–1993)
- A/C magnetic-clutch feed voltage (1992–1993)
- A/C condenser-fan connected voltage checks (1992–1993)
- A/C insufficient-cooling pressure check at 2,000 rpm (1990–1993)
- A/C sight-glass charge observation (1992–1993)