Heating & Air Conditioning

Torque specs

Air Conditioning

A/C compressor hose connection bolts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Refrigerant line bracket bolts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Refrigerant pipe joint nuts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
79–112 in·lb in·lb8.9–12.7 N·m8.9–12.7 N·m79–112 in·lb in·lb
A/C condenser mounting bolts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Evaporator cooling unit mounting nuts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Refrigerant pressure switch (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
79–95 in·lb in·lb8.9–10.7 N·m8.9–10.7 N·m79–95 in·lb in·lb
Condenser fan bracket bolt (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
79–112 in·lb in·lb8.9–12.7 N·m8.9–12.7 N·m79–112 in·lb in·lb
Condenser fan mounting bolts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C evaporator unit mounting nut
NA 1994–1997 (BP) — Other years inferred from 1994 factory evidence.
≈70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m≈70–95 in·lb in·lb
A/C condenser inlet fitting (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
11–18 ft·lb15–24 N·m15–24 N·m11–18 ft·lb
A/C evaporator outlet fitting (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
15–21 ft·lb20–29 N·m20–29 N·m15–21 ft·lb
A/C compressor inlet and outlet fittings (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
8–11 ft·lb10–15 N·m10–15 N·m8–11 ft·lb
A/C evaporator inlet fitting (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
8–14 ft·lb10–19 N·m10–19 N·m8–14 ft·lb

Factory hvac service audit

Heater Blower

Heater unit mounting nuts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Blower unit mounting nuts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb

Additional 1994 factory service specifications

Heater unit mounting nuts (NA 1.8)
NA 1994–1997 (BP)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Blower unit mounting bolt and nuts (NA 1.8)
NA 1994–1997 (BP)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C cooling unit mounting bolt (NA 1.8)
NA 1994–1997 (BP)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C condenser mounting bolts (NA 1.8)
NA 1994–1997 (BP)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C compressor discharge valve plate bolts (NA 1.8)
NA 1994–1997 (BP)
41 in·lb in·lb4.6 N·m4.6 N·m41 in·lb in·lb
A/C compressor service valve bolts (NA 1.8)
NA 1994–1997 (BP)
109 in·lb in·lb12.3 N·m12.3 N·m109 in·lb in·lb

Additional 1999 factory specifications

Factory air conditioning pressure inspection (1990)

A/C condenser inlet fitting (1992)
NA 1992 (B6)
11–18 ft·lb15–25 N·m15–25 N·m11–18 ft·lb
A/C compressor-to-bracket mounting bolts (1992)
NA 1992 (B6)
11–16 ft·lb14.7–21.6 N·m14.7–21.6 N·m11–16 ft·lb

Additional 1994 service specifications

Fluids & capacities

Fluids & capacities

A/C refrigerant type & charge (2004)
NB 2004 (BP-Z3)
14.1 oz400 g400 g14.1 ozR-134a refrigerant
A/C compressor oil — sealed volume (2004)
NB 2004 (BP-Z3)
5.07 US fl oz150 ml150 ml5.07 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new cooler hose or pipe (2004)
NB 2004 (BP-Z3)
0.3 US fl oz10 ml10 ml0.3 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new condenser (2004)
NB 2004 (BP-Z3)
1 US fl oz30 ml30 ml1 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new cooling unit (2004–2005)
NB 2004–2005 (BP-Z3)
1.4 US fl oz40 ml40 ml1.4 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new evaporator (2004)
NB 2004 (BP-Z3)
1.4 US fl oz40 ml40 ml1.4 US fl ozDENSO OIL9 compressor oil

Service measurements and fasteners

Factory service specifications

Additional 1999 factory specifications

Additional factory specifications

Additional 1994 service specifications

Service specs

Factory hvac service audit

Heater blower-motor supply voltage (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Ignition ON and blower at fourth speed: blue (L) blower-motor feed should read battery voltage relative to body ground.Ignition ON and blower at fourth speed: blue (L) blower-motor feed should read battery voltage relative to body ground.
Heater blower-resistor connected voltage checks (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Ignition ON, blower and A/C OFF: battery voltage at the resistor single-contact blue/red (L/R) feed and at each four-contact plug wire — blue/white (L/W), blue/red (L/R), blue/green (L/G), blue/yellow (L/Y).Ignition ON, blower and A/C OFF: battery voltage at the resistor single-contact blue/red (L/R) feed and at each four-contact plug wire — blue/white (L/W), blue/red (L/R), blue/green (L/G), blue/yellow (L/Y).
Heater blower-switch connected voltage checks (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Ignition ON: fourth blower speed → black (B) switch ground wire 0 V; blower and A/C OFF → battery voltage on blue/white, blue/red, blue/green and blue/yellow at the connected blower switch.Ignition ON: fourth blower speed → black (B) switch ground wire 0 V; blower and A/C OFF → battery voltage on blue/white, blue/red, blue/green and blue/yellow at the connected blower switch.
A/C magnetic-clutch feed voltage (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Engine idling with A/C and blower ON: black/red (B/R) at the connected magnetic-clutch plug should read battery voltage relative to body ground.Engine idling with A/C and blower ON: black/red (B/R) at the connected magnetic-clutch plug should read battery voltage relative to body ground.
A/C condenser-fan connected voltage checks (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
With the original A/C requesting condenser-fan operation: black/blue (B/L) fan feed → battery voltage; black (B) fan ground → 0 V relative to body ground.With the original A/C requesting condenser-fan operation: black/blue (B/L) fan feed → battery voltage; black (B) fan ground → 0 V relative to body ground.
A/C insufficient-cooling pressure check at 2,000 rpm (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Insufficient-cooling diagnostic at 2,000 rpm and maximum cooling: low side 21–43 psi (147–294 kPa; 1.5–3.0 kg/cm²); high side 1,177–1,171–235 psi (619 kPa; 12.0–16.5 kg/cm²).Insufficient-cooling diagnostic at 2,000 rpm and maximum cooling: low side 147–294 kPa (1.5–3.0 kg/cm², 21–43 psi); high side 1,177–1,619 kPa (12.0–16.5 kg/cm², 171–235 psi).
A/C sight-glass charge observation (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Original R-12 sight glass: bubbles while cooling suggest insufficient charge; a clear glass alone can indicate correct or excessive charge. Immediately after A/C OFF, foaming followed by clearing is the factory normal observation.Original R-12 sight glass: bubbles while cooling suggest insufficient charge; a clear glass alone can indicate correct or excessive charge. Immediately after A/C OFF, foaming followed by clearing is the factory normal observation.
Heater blower-resistor isolated continuity (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Disconnected resistor assembly: continuity from its common single-contact blue/red lead to each four-contact connector tap — blue/yellow (Lo), blue/green (Me), blue/red (Mh) and blue/white (Hi).Disconnected resistor assembly: continuity from its common single-contact blue/red lead to each four-contact connector tap — blue/yellow (Lo), blue/green (Me), blue/red (Mh) and blue/white (Hi).
A/C compressor overhaul oil refill calculation (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
After the specified compressor overhaul: refill with the amount of compressor oil drained, plus 20 cc (1.2 cu in). Use Mazda NA02 61 K39 or equivalent.After the specified compressor overhaul: refill with the amount of compressor oil drained, plus 20 cc (1.2 cu in). Use Mazda NA02 61 K39 or equivalent.
A/C magnetic clutch clearance and shims (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Standard clearance 0.014–0.025 in (0.35–0.65 mm); available shims 0.004 in (0.1 mm), 0.012 in (0.3 mm), 0.020 in (0.5 mm).Standard clearance 0.35–0.65 mm (0.014–0.025 in); available shims 0.1 mm (0.004 in), 0.3 mm (0.012 in), 0.5 mm (0.020 in).
A/C short-cycling low-pressure diagnosis (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
At clutch disengagement: 24 psi (167 kPa; 1.7 kgf/cm²) or lower — evacuate/recharge; 30 psi (206 kPa; 2.1 kgf/cm²) or higher — inspect thermoswitch.At clutch disengagement: 167 kPa (1.7 kgf/cm², 24 psi) or lower — evacuate/recharge; 206 kPa (2.1 kgf/cm², 30 psi) or higher — inspect thermoswitch.
A/C evacuation and vacuum retention check (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.
A/C preliminary refrigerant leak-test pressure (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
After evacuation and the vacuum retention check, admit refrigerant through the low-side manifold valve to a low-side reading of 14 psi (0.1 MPa; 1 kgf/cm²); close the valve and check pipe/hose joints with a gas leak tester.After evacuation and the vacuum retention check, admit refrigerant through the low-side manifold valve to a low-side reading of 0.1 MPa {1 kgf/cm², 14 psi}; close the valve and check pipe/hose joints with a gas leak tester.
A/C staged refrigerant charging by tank weight (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
With the engine stopped, charge to a tank-weight decrease of 200 g {7.0 oz}. Then close the low-side valve, start the engine and engage A/C; charge to a total tank-weight decrease of 400 g {14.1 oz} from the same initial weighing.With the engine stopped, charge to a tank-weight decrease of 200 g {7.0 oz}. Then close the low-side valve, start the engine and engage A/C; charge to a total tank-weight decrease of 400 g {14.1 oz} from the same initial weighing.
HVAC fresh/recirculated-air cable adjustment position — non-turbo (2001–2005)
NB 2003–2005 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Cabin intake lever and blower-unit intake link both at recirculate when attaching and clamping the cable; verify full lever travel.Cabin intake lever and blower-unit intake link both at recirculate when attaching and clamping the cable; verify full lever travel.
HVAC temperature cable adjustment position — non-turbo (2001–2005)
NB 2003–2005 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Temperature dial and heater-unit air-mix link both at maximum heat when attaching and clamping the cable; verify full dial travel.Temperature dial and heater-unit air-mix link both at maximum heat when attaching and clamping the cable; verify full dial travel.
HVAC outlet-mode cable adjustment position — non-turbo (2001–2005)
NB 2003–2005 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Outlet-mode dial and heater-unit mode link both at VENT (face vents) when attaching and clamping the cable; verify full dial travel.Outlet-mode dial and heater-unit mode link both at VENT (face vents) when attaching and clamping the cable; verify full dial travel.
A/C refrigerant-line joint preparation and tightening method — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Oil the O-rings with compressor oil; start the joint nut or bolt by hand, then tighten to that joint’s specified torque. Use a spanner with the torque wrench on nut joints.Oil the O-rings with compressor oil; start the joint nut or bolt by hand, then tighten to that joint’s specified torque. Use a spanner with the torque wrench on nut joints.
Air conditioning refrigerant and compressor inspection interval — U.S. schedules (2001–2003)
NB 2003 — U.S.A. Schedule 1 normal driving or Schedule 2 unique driving conditions, as stated. Non-U.S. market applicability is not established here.; NB 2001–2002 — U.S.A. Schedule 1 normal driving or Schedule 2 unique driving conditions, as stated. Non-U.S. market applicability is not established here. 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with the applicable factory schedule, facts and service context compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
If air conditioning is installed, Schedules 1 and 2 specify refrigerant amount and compressor operation inspections every 12 months or 24,000 kilometers (15,000 miles), whichever comes first. This is an inspection interval, not an instruction to add refrigerant periodically.If air conditioning is installed, Schedules 1 and 2 specify refrigerant amount and compressor operation inspections every 12 months or 24,000 kilometers (15,000 miles), whichever comes first. This is an inspection interval, not an instruction to add refrigerant periodically.
A/C replacement compressor oil removal calculation — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Approximate oil to REMOVE from the new compressor = 150 ml {150 cc, 5.07 fl oz} − [oil from the old compressor + 15 ml {15 cc, 0.5 fl oz}].Approximate oil to REMOVE from the new compressor = 150 ml {150 cc, 5.07 fl oz} − [oil from the old compressor + 15 ml {15 cc, 0.5 fl oz}].

Additional 1999 factory specifications

Factory HVAC service references (2005)

A/C short-cycling pressure diagnosis (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
At clutch disengagement: 24 psi (167 kPa; 1.7 kgf/cm²) or lower — evacuate/recharge; 30 psi (206 kPa; 2.1 kgf/cm²) or higher — inspect thermoswitch.At clutch disengagement: 167 kPa (1.7 kgf/cm², 24 psi) or lower — evacuate/recharge; 206 kPa (2.1 kgf/cm², 30 psi) or higher — inspect thermoswitch.
A/C evacuation and vacuum retention (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.
A/C refrigerant recovery equipment (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Recover R-134a with service equipment certified to SAE J2210; connect the recovery/recycling/recharging device and follow its manufacturer’s instructions.Recover R-134a with service equipment certified to SAE J2210; connect the recovery/recycling/recharging device and follow its manufacturer’s instructions.
A/C refrigerant joint preparation (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Oil the O-rings with compressor oil; start the joint nut or bolt by hand, then tighten to that joint’s specified torque. Use a spanner with the torque wrench on nut joints.Oil the O-rings with compressor oil; start the joint nut or bolt by hand, then tighten to that joint’s specified torque. Use a spanner with the torque wrench on nut joints.
A/C panel switch continuity and LED (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
A–B: OFF open, ON continuity. With C at battery positive and A grounded, the indicator LED illuminates when switched ON.A–B: OFF open, ON continuity. With C at battery positive and A grounded, the indicator LED illuminates when switched ON.

Factory air conditioning pressure inspection (1990)

Original A/C running refrigerant pressures (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Low side: 21–43 psi (147–294 kPa; 1.5–3.0 kg/cm²). High side: 1,177–1,171–235 psi (619 kPa; 12.0–16.5 kg/cm²).Low side: 147–294 kPa (1.5–3.0 kg/cm², 21–43 psi). High side: 1,177–1,619 kPa (12.0–16.5 kg/cm², 171–235 psi).
Heater temperature blend control-wire adjustment (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Set the temperature blend lever to MAX-HOT; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.Set the temperature blend lever to MAX-HOT; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.
Heater blower-motor connected feed voltage (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Ignition ON and blower switch in fourth position: blue (L) motor feed 12 V relative to body ground.Ignition ON and blower switch in fourth position: blue (L) motor feed 12 V relative to body ground.
Heater blower-resistor connected voltage checks (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Ignition ON, blower and A/C OFF: separate single-contact blue/red (L/R) resistor lead and four-contact plug wires L/W, L/R, L/G and L/Y each 12 V to body ground.Ignition ON, blower and A/C OFF: separate single-contact blue/red (L/R) resistor lead and four-contact plug wires L/W, L/R, L/G and L/Y each 12 V to body ground.
Heater blower-switch connected voltage checks (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Ignition ON, blower in fourth position: black (B) switch ground 0 V. Then blower and A/C OFF: switch L/W, L/R, L/G and L/Y each 12 V to body ground.Ignition ON, blower in fourth position: black (B) switch ground 0 V. Then blower and A/C OFF: switch L/W, L/R, L/G and L/Y each 12 V to body ground.
A/C magnetic-clutch connected feed voltage (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Engine idling, A/C and blower ON: black/red (B/R) magnetic-clutch connector feed 12 V to body ground.Engine idling, A/C and blower ON: black/red (B/R) magnetic-clutch connector feed 12 V to body ground.
A/C condenser-fan connected voltage checks (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
During the original A/C condenser-fan request: black/blue (B/L) fan feed 12 V and black (B) ground 0 V relative to body ground.During the original A/C condenser-fan request: black/blue (B/L) fan feed 12 V and black (B) ground 0 V relative to body ground.
Original A/C refrigerant sight-glass indications (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Bubbles during operation indicate insufficient refrigerant; no bubbles can mean correct charge or excess. Immediately after A/C is switched OFF, continued clarity indicates excess, while foaming followed by clarity indicates the proper amount.Bubbles during operation indicate insufficient refrigerant; no bubbles can mean correct charge or excess. Immediately after A/C is switched OFF, continued clarity indicates excess, while foaming followed by clarity indicates the proper amount.
Heater temperature blend control-wire adjustment (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Set the temperature blend lever to maximum hot; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.Set the temperature blend lever to maximum hot; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.
A/C compressor oil type and handling (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Use only DENSO OIL9; cap oil and opened refrigerant components immediately against moisture.Use only DENSO OIL9; cap oil and opened refrigerant components immediately against moisture.
Heater air intake wire adjustment (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Set REC/FRESH lever and air intake link to REC; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.Set REC/FRESH lever and air intake link to REC; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.
Heater air mix wire adjustment (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Set temperature control dial and air mix link to MAX HOT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.Set temperature control dial and air mix link to MAX HOT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.
Heater airflow mode wire adjustment (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Set airflow mode control dial and airflow mode link to VENT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.Set airflow mode control dial and airflow mode link to VENT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.
A/C magnetic clutch operation check (2001–2004)
NB 2001–2004 (BP-Z3) — 2002 applicability is supported by matching text in publication 1719-1U-01G; 2001 follows the owner-approved early-NB2 carry-over policy and is not an independently verified year.
With the clutch connector disconnected, apply battery positive to clutch terminal A and ground the compressor body; the magnetic clutch must operate.With the clutch connector disconnected, apply battery positive to clutch terminal A and ground the compressor body; the magnetic clutch must operate.

Additional 1994 service specifications

A/C drive belt deflection — new belt (NA 1.8)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
0.31–0.35 in (8.0–9.0 mm) under 22 lbf (98 N; 10 kgf)8.0–9.0 mm {0.31–0.35 in} under 98 N {10 kgf, 22 lbf}
A/C drive belt deflection — used belt (NA 1.8)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
0.35–0.39 in (9.0–10.0 mm) under 22 lbf (98 N; 10 kgf)9.0–10.0 mm {0.35–0.39 in} under 98 N {10 kgf, 22 lbf}