Updated specs are available.
Heating & Air Conditioning
0 spec(s) here don't apply to your car.
No specs here apply to your Miata
Try a different system or check your car selection. Hidden values are for other cars; they are not substitutes for your factory manual.
Browse systemsTorque specs
Air Conditioning
A/C compressor bracket large bolt (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
28–38 ft·lb38–51 N·m38–51 N·m28–38 ft·lb
A/C compressor bracket small bolt (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
14–18 ft·lb19–25 N·m19–25 N·m14–18 ft·lb
A/C compressor hose connection bolts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Refrigerant line bracket bolts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Refrigerant pipe joint nuts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
79–112 in·lb in·lb8.9–12.7 N·m8.9–12.7 N·m79–112 in·lb in·lb
A/C condenser mounting bolts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Evaporator cooling unit mounting nuts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Refrigerant pressure switch (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
79–95 in·lb in·lb8.9–10.7 N·m8.9–10.7 N·m79–95 in·lb in·lb
Condenser fan bracket bolt (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
79–112 in·lb in·lb8.9–12.7 N·m8.9–12.7 N·m79–112 in·lb in·lb
Condenser fan mounting bolts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C evaporator unit mounting nut
NA 1994–1997 (BP) — Other years inferred from 1994 factory evidence.
≈70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m≈70–95 in·lb in·lb
A/C condenser inlet fitting (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
11–18 ft·lb15–24 N·m15–24 N·m11–18 ft·lb
A/C evaporator outlet fitting (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
15–21 ft·lb20–29 N·m20–29 N·m15–21 ft·lb
A/C compressor inlet and outlet fittings (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
8–11 ft·lb10–15 N·m10–15 N·m8–11 ft·lb
A/C evaporator inlet fitting (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
8–14 ft·lb10–19 N·m10–19 N·m8–14 ft·lb
A/C receiver/drier inlet and outlet fittings (NA 1.8L)
NA 1994 (BP); NA 1997 (BP)
8–14 ft·lb10–19 N·m10–19 N·m8–14 ft·lb
Factory hvac service audit
A/C compressor discharge valve retaining-plate bolts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
41 in·lb in·lb4.6 N·m4.6 N·m41 in·lb in·lb
A/C compressor front/rear housing through bolts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
226 in·lb in·lb25.5 N·m25.5 N·m226 in·lb in·lb
A/C compressor discharge valve body through bolts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
96 in·lb in·lb10.8 N·m10.8 N·m96 in·lb in·lb
A/C compressor discharge valve body installation bolts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
96 in·lb in·lb10.8 N·m10.8 N·m96 in·lb in·lb
A/C compressor service-valve attachment bolts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
109 in·lb in·lb12.3 N·m12.3 N·m109 in·lb in·lb
Heater unit mounting nuts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
69–95 in·lb in·lb7.8–11 N·m7.8–11 N·m69–95 in·lb in·lb
Blower unit mounting bolt and nuts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
69–95 in·lb in·lb7.8–11 N·m7.8–11 N·m69–95 in·lb in·lb
A/C cooling-unit casing mounting nuts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
69–95 in·lb in·lb7.8–11 N·m7.8–11 N·m69–95 in·lb in·lb
A/C condenser mounting bolts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
69–95 in·lb in·lb7.8–11 N·m7.8–11 N·m69–95 in·lb in·lb
A/C condenser-fan assembly mounting bolts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
69–95 in·lb in·lb7.8–11 N·m7.8–11 N·m69–95 in·lb in·lb
A/C internal expansion-valve inlet pipe fitting (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
9–11 ft·lb12–15 N·m12–15 N·m9–11 ft·lb
A/C internal expansion-valve outlet pipe fitting (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
22–25 ft·lb29–34 N·m29–34 N·m22–25 ft·lb
A/C receiver/drier inlet and outlet pipe fittings (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
A/C inline pipe-to-hose unions (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
A/C condenser outlet pipe fitting (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
A/C magnetic clutch pressure-plate center bolt — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
8–11 ft·lb10.8–15.6 N·m10.8–15.6 N·m8–11 ft·lb
Heater Blower
Heater unit mounting nuts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Blower unit mounting nuts (NB2)
NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Additional 1994 factory service specifications
Heater unit mounting nuts (NA 1.8)
NA 1994–1997 (BP)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Blower unit mounting bolt and nuts (NA 1.8)
NA 1994–1997 (BP)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C cooling unit mounting bolt (NA 1.8)
NA 1994–1997 (BP)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C condenser mounting bolts (NA 1.8)
NA 1994–1997 (BP)
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C compressor discharge valve plate bolts (NA 1.8)
NA 1994–1997 (BP)
41 in·lb in·lb4.6 N·m4.6 N·m41 in·lb in·lb
A/C compressor housing through bolts (NA 1.8)
NA 1994–1997 (BP)
19 ft·lb25 N·m25 N·m19 ft·lb
A/C compressor discharge valve body bolts and through bolts (NA 1.8)
NA 1994–1997 (BP)
96 in·lb in·lb10.8 N·m10.8 N·m96 in·lb in·lb
A/C compressor service valve bolts (NA 1.8)
NA 1994–1997 (BP)
109 in·lb in·lb12.3 N·m12.3 N·m109 in·lb in·lb
Additional 1999 factory specifications
Blower unit mounting bolt and nuts (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C cooling unit mounting nuts (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Heater unit mounting nuts (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
A/C cooling unit inlet pipe fitting (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
87–173 in·lb in·lb9.9–19.6 N·m9.9–19.6 N·m87–173 in·lb in·lb
A/C cooling unit outlet pipe fitting (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
15–21 ft·lb20–29 N·m20–29 N·m15–21 ft·lb
A/C condenser mounting bolts (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
61–87 in·lb in·lb6.87–9.8 N·m6.87–9.8 N·m61–87 in·lb in·lb
A/C receiver/drier bracket nut (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
61–87 in·lb in·lb6.87–9.8 N·m6.87–9.8 N·m61–87 in·lb in·lb
A/C condenser inlet fitting (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
11–18 ft·lb15–24 N·m15–24 N·m11–18 ft·lb
A/C magnetic clutch pressure plate bolt (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
8–11 ft·lb10.8–16.2 N·m10.8–16.2 N·m8–11 ft·lb
A/C refrigerant pressure switch (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
79–95 in·lb in·lb8.9–10.7 N·m8.9–10.7 N·m79–95 in·lb in·lb
Factory air conditioning pressure inspection (1990)
A/C external cooling-unit inlet pipe fitting (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
A/C external cooling-unit outlet pipe fitting (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
14–22 ft·lb20–29 N·m20–29 N·m14–22 ft·lb
A/C internal expansion-valve inlet pipe fitting (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
9–11 ft·lb12–15 N·m12–15 N·m9–11 ft·lb
A/C internal expansion-valve outlet pipe fitting (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
22–25 ft·lb29–34 N·m29–34 N·m22–25 ft·lb
A/C receiver/drier inlet and outlet pipe fittings (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
A/C condenser inlet pipe fitting (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
11–18 ft·lb15–25 N·m15–25 N·m11–18 ft·lb
A/C condenser outlet pipe fitting (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
A/C inline rigid-pipe to compressor-hose unions (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
A/C compressor inlet and outlet hose fittings (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
7–12 ft·lb9.8–16 N·m9.8–16 N·m7–12 ft·lb
A/C cooling-unit external inlet fitting (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
A/C cooling-unit external outlet fitting (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
14–22 ft·lb20–29 N·m20–29 N·m14–22 ft·lb
A/C condenser inlet fitting (1992)
NA 1992 (B6)
11–18 ft·lb15–25 N·m15–25 N·m11–18 ft·lb
A/C compressor suction and discharge hose attachment bolts (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
7–12 ft·lb9.8–16 N·m9.8–16 N·m7–12 ft·lb
A/C compressor-to-bracket mounting bolts (1992)
NA 1992 (B6)
11–16 ft·lb14.7–21.6 N·m14.7–21.6 N·m11–16 ft·lb
A/C compressor hose retaining bolts (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
87–138 in·lb in·lb9.9–15.6 N·m9.9–15.6 N·m87–138 in·lb in·lb
A/C compressor mounting bolts (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
11–15 ft·lb15–21 N·m15–21 N·m11–15 ft·lb
A/C condenser fan upper installation bolt (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
70–95 in·lb in·lb7.9–10.7 N·m7.9–10.7 N·m70–95 in·lb in·lb
Additional 1994 service specifications
A/C expansion valve inlet pipe fitting (NA 1.8)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
105–130 in·lb in·lb11.8–14.7 N·m11.8–14.7 N·m105–130 in·lb in·lb
A/C expansion valve to evaporator fitting (NA 1.8)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
22–25 ft·lb30–34 N·m30–34 N·m22–25 ft·lb
Fluids & capacities
Fluids & capacities
A/C refrigerant type & charge (2001–2003)
NB 2001–2003 (BP-Z3) — 2001–2002 applicability inferred from actual 2003 factory evidence within the NB2 group. These entries retain the DENSO OIL9 system; different 2004/2005 actual-year records remain separate.
14.1 oz400 g400 g14.1 ozR-134a refrigerant
A/C compressor oil — sealed volume (2001–2003)
NB 2001–2003 (BP-Z3) — 2001–2002 applicability inferred from actual 2003 factory evidence within the NB2 group. These entries retain the DENSO OIL9 system; different 2004/2005 actual-year records remain separate.
5.07 US fl oz150 ml150 ml5.07 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new cooler hose or pipe (2001–2003)
NB 2001–2003 (BP-Z3) — 2001–2002 applicability inferred from actual 2003 factory evidence within the NB2 group. These entries retain the DENSO OIL9 system; different 2004/2005 actual-year records remain separate.
0.3 US fl oz10 ml10 ml0.3 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new condenser (2001–2003)
NB 2001–2003 (BP-Z3) — 2001–2002 applicability inferred from actual 2003 factory evidence within the NB2 group. These entries retain the DENSO OIL9 system; different 2004/2005 actual-year records remain separate.
1 US fl oz30 ml30 ml1 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new cooling unit (2001–2003)
NB 2001–2003 (BP-Z3) — 2001–2002 applicability inferred from actual 2003 factory evidence within the NB2 group. These entries retain the DENSO OIL9 system; different 2004/2005 actual-year records remain separate.
1.4 US fl oz40 ml40 ml1.4 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new evaporator (2001–2003)
NB 2001–2003 (BP-Z3) — 2001–2002 applicability inferred from actual 2003 factory evidence within the NB2 group. These entries retain the DENSO OIL9 system; different 2004/2005 actual-year records remain separate.
1.4 US fl oz40 ml40 ml1.4 US fl ozDENSO OIL9 compressor oil
A/C refrigerant type & charge (2004)
NB 2004 (BP-Z3)
14.1 oz400 g400 g14.1 ozR-134a refrigerant
A/C compressor oil — sealed volume (2004)
NB 2004 (BP-Z3)
5.07 US fl oz150 ml150 ml5.07 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new cooler hose or pipe (2004)
NB 2004 (BP-Z3)
0.3 US fl oz10 ml10 ml0.3 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new condenser (2004)
NB 2004 (BP-Z3)
1 US fl oz30 ml30 ml1 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new cooling unit (2004–2005)
NB 2004–2005 (BP-Z3)
1.4 US fl oz40 ml40 ml1.4 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new evaporator (2004)
NB 2004 (BP-Z3)
1.4 US fl oz40 ml40 ml1.4 US fl ozDENSO OIL9 compressor oil
A/C oil addition — new evaporator (1990–1993)
NA 1990–1993 (B6) — 1990 and 1992 factory evidence; 1991/1993 applicability inferred within the NA6 group, for the original factory R-12 system.
3.05 cu in50 cc50 cc3.05 cu in
A/C oil addition — new condenser (1990–1993)
NA 1990–1993 (B6) — 1990 and 1992 factory evidence; 1991/1993 applicability inferred within the NA6 group, for the original factory R-12 system.
1.83 cu in30 cc30 cc1.83 cu in
A/C oil addition — new receiver/drier (1990–1993)
NA 1990–1993 (B6) — 1990 and 1992 factory evidence; 1991/1993 applicability inferred within the NA6 group, for the original factory R-12 system.
0.61 cu in10 cc10 cc0.61 cu in
A/C compressor oil specification (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Compressor oil; MAZDA Part number NA02 61 K39 or equivalent
A/C compressor oil — published amount (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
≈2.705–3.381 US fl oz80–100 cc80–100 cc≈2.705–3.381 US fl oz
Service measurements and fasteners
A/C oil addition — new complete cooling unit (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
1.4 US fl oz40 ml40 ml1.4 US fl ozDENSO OIL8 compressor oil
Factory service specifications
A/C oil addition — new evaporator (NA 1.8)
NA 1994–1997 (BP) — Other years inferred from 1994 factory evidence.
≈1.691 US fl oz50 ml50 ml≈1.691 US fl oz
A/C oil addition — new condenser (NA 1.8)
NA 1994–1997 (BP) — Other years inferred from 1994 factory evidence.
≈1.014 US fl oz30 ml30 ml≈1.014 US fl oz
A/C compressor overhaul oil addition (NA 1.8)
NA 1994–1997 (BP) — Other years inferred from 1994 factory evidence.
≈0.676 US fl oz20 ml20 ml≈0.676 US fl oz
Additional 1999 factory specifications
Compressor oil supplement — new cooling unit (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
1.4 US fl oz40 ml40 ml1.4 US fl oz
Compressor oil supplement — new evaporator (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
1.4 US fl oz40 ml40 ml1.4 US fl oz
Compressor oil supplement — new condenser (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
1 US fl oz30 ml30 ml1 US fl oz
Compressor oil supplement — new receiver/drier (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
0.3 US fl oz10 ml10 ml0.3 US fl oz
Additional factory specifications
A/C refrigerant type & charge (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
14.1 oz400 g400 g14.1 ozR-134a refrigerant
A/C compressor oil — sealed volume (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
2.03 US fl oz60 ml60 ml2.03 US fl ozDENSO OIL8 compressor oil
A/C oil addition — new cooler hose or pipe (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
0.3 US fl oz10 ml10 ml0.3 US fl ozDENSO OIL8 compressor oil
A/C oil addition — new condenser (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
1 US fl oz30 ml30 ml1 US fl ozDENSO OIL8 compressor oil
A/C oil addition — new evaporator (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
1.4 US fl oz40 ml40 ml1.4 US fl ozDENSO OIL8 compressor oil
Additional 1994 service specifications
A/C refrigerant charge (1994)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
21.2 oz600 g600 g21.2 oz
A/C compressor oil specification (1994)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
PAG compressor oil; ND–OIL9
A/C oil addition — new receiver-drier (1994)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
0.3 US fl oz10 ml10 ml0.3 US fl oz
Service specs
Factory hvac service audit
Heater blower-speed switch continuity (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
OFF: no blower-switch continuity. First: a–g. Second: c–g–h. Third: e–g–h. Fourth: b–g–h.OFF: no blower-switch continuity. First: a–g. Second: c–g–h. Third: e–g–h. Fourth: b–g–h.
Heater blower-motor supply voltage (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Ignition ON and blower at fourth speed: blue (L) blower-motor feed should read battery voltage relative to body ground.Ignition ON and blower at fourth speed: blue (L) blower-motor feed should read battery voltage relative to body ground.
Heater blower-resistor connected voltage checks (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Ignition ON, blower and A/C OFF: battery voltage at the resistor single-contact blue/red (L/R) feed and at each four-contact plug wire — blue/white (L/W), blue/red (L/R), blue/green (L/G), blue/yellow (L/Y).Ignition ON, blower and A/C OFF: battery voltage at the resistor single-contact blue/red (L/R) feed and at each four-contact plug wire — blue/white (L/W), blue/red (L/R), blue/green (L/G), blue/yellow (L/Y).
Heater blower-switch connected voltage checks (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Ignition ON: fourth blower speed → black (B) switch ground wire 0 V; blower and A/C OFF → battery voltage on blue/white, blue/red, blue/green and blue/yellow at the connected blower switch.Ignition ON: fourth blower speed → black (B) switch ground wire 0 V; blower and A/C OFF → battery voltage on blue/white, blue/red, blue/green and blue/yellow at the connected blower switch.
A/C magnetic-clutch feed voltage (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Engine idling with A/C and blower ON: black/red (B/R) at the connected magnetic-clutch plug should read battery voltage relative to body ground.Engine idling with A/C and blower ON: black/red (B/R) at the connected magnetic-clutch plug should read battery voltage relative to body ground.
A/C condenser-fan connected voltage checks (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
With the original A/C requesting condenser-fan operation: black/blue (B/L) fan feed → battery voltage; black (B) fan ground → 0 V relative to body ground.With the original A/C requesting condenser-fan operation: black/blue (B/L) fan feed → battery voltage; black (B) fan ground → 0 V relative to body ground.
A/C insufficient-cooling pressure check at 2,000 rpm (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Insufficient-cooling diagnostic at 2,000 rpm and maximum cooling: low side 21–43 psi (147–294 kPa; 1.5–3.0 kg/cm²); high side 1,177–1,171–235 psi (619 kPa; 12.0–16.5 kg/cm²).Insufficient-cooling diagnostic at 2,000 rpm and maximum cooling: low side 147–294 kPa (1.5–3.0 kg/cm², 21–43 psi); high side 1,177–1,619 kPa (12.0–16.5 kg/cm², 171–235 psi).
A/C sight-glass charge observation (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Original R-12 sight glass: bubbles while cooling suggest insufficient charge; a clear glass alone can indicate correct or excessive charge. Immediately after A/C OFF, foaming followed by clearing is the factory normal observation.Original R-12 sight glass: bubbles while cooling suggest insufficient charge; a clear glass alone can indicate correct or excessive charge. Immediately after A/C OFF, foaming followed by clearing is the factory normal observation.
Heater blower-motor direct battery check (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Isolated blower motor: battery positive to blue (L) supply contact, ground to blue/red (L/R) return contact; motor should run.Isolated blower motor: battery positive to blue (L) supply contact, ground to blue/red (L/R) return contact; motor should run.
Heater blower-resistor isolated continuity (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Disconnected resistor assembly: continuity from its common single-contact blue/red lead to each four-contact connector tap — blue/yellow (Lo), blue/green (Me), blue/red (Mh) and blue/white (Hi).Disconnected resistor assembly: continuity from its common single-contact blue/red lead to each four-contact connector tap — blue/yellow (Lo), blue/green (Me), blue/red (Mh) and blue/white (Hi).
R-12 refrigerant container storage temperature (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Store the R-12 refrigerant container below 125.6 °F (52 °C); do not expose it to high heat.Store the R-12 refrigerant container below 52°C (125.6°F); do not expose it to high heat.
A/C condenser-fan direct battery check (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Disconnected condenser fan: battery positive to black/blue (B/L) supply, ground to black (B) return; the motor should run.Disconnected condenser fan: battery positive to black/blue (B/L) supply, ground to black (B) return; the motor should run.
A/C compressor overhaul oil refill calculation (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
After the specified compressor overhaul: refill with the amount of compressor oil drained, plus 20 cc (1.2 cu in). Use Mazda NA02 61 K39 or equivalent.After the specified compressor overhaul: refill with the amount of compressor oil drained, plus 20 cc (1.2 cu in). Use Mazda NA02 61 K39 or equivalent.
A/C evaporator thermoswitch continuity (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Above 32 °F (0 °C): continuity; below 32 °F (0 °C): no continuity.Above 0°C (32°F): continuity; below 0°C (32°F): no continuity.
A/C magnetic clutch clearance and shims (1990–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Standard clearance 0.016–0.024 in (0.4–0.6 mm); available shims 0.004 in (0.10 mm), 0.012 in (0.30 mm), 0.020 in (0.50 mm).Standard clearance 0.4–0.6 mm (0.016–0.024 in); available shims 0.10 mm (0.004 in), 0.30 mm (0.012 in), 0.50 mm (0.020 in).
A/C magnetic clutch clearance and shims (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Standard clearance 0.014–0.025 in (0.35–0.65 mm); available shims 0.004 in (0.1 mm), 0.012 in (0.3 mm), 0.020 in (0.5 mm).Standard clearance 0.35–0.65 mm (0.014–0.025 in); available shims 0.1 mm (0.004 in), 0.3 mm (0.012 in), 0.5 mm (0.020 in).
A/C short-cycling low-pressure diagnosis (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
At clutch disengagement: 24 psi (167 kPa; 1.7 kgf/cm²) or lower — evacuate/recharge; 30 psi (206 kPa; 2.1 kgf/cm²) or higher — inspect thermoswitch.At clutch disengagement: 167 kPa (1.7 kgf/cm², 24 psi) or lower — evacuate/recharge; 206 kPa (2.1 kgf/cm², 30 psi) or higher — inspect thermoswitch.
A/C panel switch continuity and indicator — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
A–B: OFF open, ON continuity. With C at battery positive and A grounded, the indicator LED illuminates when switched ON.A–B: OFF open, ON continuity. With C at battery positive and A grounded, the indicator LED illuminates when switched ON.
A/C thermoswitch connected voltage reference — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Connected A positive to B negative: magnetic clutch ON battery voltage; magnetic clutch OFF 0 V.Connected A positive to B negative: magnetic clutch ON battery voltage; magnetic clutch OFF 0 V.
A/C thermoswitch water-temperature voltage thresholds — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Sensor water temperature 38 °F (3.6 °C) or more: battery voltage A-to-B. At 33 °F (0.8 °C) or less: 0 V.Sensor water temperature 3.6 °C {38 °F} or more: battery voltage A-to-B. At 0.8 °C {33 °F} or less: 0 V.
A/C evacuation and vacuum retention check (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.
A/C preliminary refrigerant leak-test pressure (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
After evacuation and the vacuum retention check, admit refrigerant through the low-side manifold valve to a low-side reading of 14 psi (0.1 MPa; 1 kgf/cm²); close the valve and check pipe/hose joints with a gas leak tester.After evacuation and the vacuum retention check, admit refrigerant through the low-side manifold valve to a low-side reading of 0.1 MPa {1 kgf/cm², 14 psi}; close the valve and check pipe/hose joints with a gas leak tester.
A/C staged refrigerant charging by tank weight (2001–2004)
NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
With the engine stopped, charge to a tank-weight decrease of 200 g {7.0 oz}. Then close the low-side valve, start the engine and engage A/C; charge to a total tank-weight decrease of 400 g {14.1 oz} from the same initial weighing.With the engine stopped, charge to a tank-weight decrease of 200 g {7.0 oz}. Then close the low-side valve, start the engine and engage A/C; charge to a total tank-weight decrease of 400 g {14.1 oz} from the same initial weighing.
HVAC fresh/recirculated-air cable adjustment position — non-turbo (2001–2005)
NB 2003–2005 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Cabin intake lever and blower-unit intake link both at recirculate when attaching and clamping the cable; verify full lever travel.Cabin intake lever and blower-unit intake link both at recirculate when attaching and clamping the cable; verify full lever travel.
HVAC temperature cable adjustment position — non-turbo (2001–2005)
NB 2003–2005 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Temperature dial and heater-unit air-mix link both at maximum heat when attaching and clamping the cable; verify full dial travel.Temperature dial and heater-unit air-mix link both at maximum heat when attaching and clamping the cable; verify full dial travel.
HVAC outlet-mode cable adjustment position — non-turbo (2001–2005)
NB 2003–2005 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Outlet-mode dial and heater-unit mode link both at VENT (face vents) when attaching and clamping the cable; verify full dial travel.Outlet-mode dial and heater-unit mode link both at VENT (face vents) when attaching and clamping the cable; verify full dial travel.
HVAC blower motor operation test — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Disconnected blower motor: battery positive to A, ground to B; motor must operate.Disconnected blower motor: battery positive to A, ground to B; motor must operate.
A/C condenser fan operation and airflow test — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Battery positive to fan terminal A and ground to B: fan must run and blow air toward the engine.Battery positive to fan terminal A and ground to B: fan must run and blow air toward the engine.
A/C compressor oil diagnostic conditioning and quantity check — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
Diagnostic oil check: 100 ml {100 cc, 3.38 fl oz} after the specified FRESH/VENT/MAX COLD conditioning cycle.Diagnostic oil check: 100 ml {100 cc, 3.38 fl oz} after the specified FRESH/VENT/MAX COLD conditioning cycle.
A/C refrigerant-line joint preparation and tightening method — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Oil the O-rings with compressor oil; start the joint nut or bolt by hand, then tighten to that joint’s specified torque. Use a spanner with the torque wrench on nut joints.Oil the O-rings with compressor oil; start the joint nut or bolt by hand, then tighten to that joint’s specified torque. Use a spanner with the torque wrench on nut joints.
Air conditioning refrigerant and compressor inspection interval — U.S. schedules (2001–2003)
NB 2003 — U.S.A. Schedule 1 normal driving or Schedule 2 unique driving conditions, as stated. Non-U.S. market applicability is not established here.; NB 2001–2002 — U.S.A. Schedule 1 normal driving or Schedule 2 unique driving conditions, as stated. Non-U.S. market applicability is not established here. 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with the applicable factory schedule, facts and service context compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
If air conditioning is installed, Schedules 1 and 2 specify refrigerant amount and compressor operation inspections every 12 months or 24,000 kilometers (15,000 miles), whichever comes first. This is an inspection interval, not an instruction to add refrigerant periodically.If air conditioning is installed, Schedules 1 and 2 specify refrigerant amount and compressor operation inspections every 12 months or 24,000 kilometers (15,000 miles), whichever comes first. This is an inspection interval, not an instruction to add refrigerant periodically.
A/C replacement compressor oil removal calculation — non-turbo (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Approximate oil to REMOVE from the new compressor = 150 ml {150 cc, 5.07 fl oz} − [oil from the old compressor + 15 ml {15 cc, 0.5 fl oz}].Approximate oil to REMOVE from the new compressor = 150 ml {150 cc, 5.07 fl oz} − [oil from the old compressor + 15 ml {15 cc, 0.5 fl oz}].
A/C refrigerant container storage temperature limit (2001–2004)
NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
Store the refrigerant container below 104 °F (40 °C).Store the refrigerant container below 40 °C {104 °F}.
Additional 1999 factory specifications
A/C magnetic clutch standard clearance (NB1)
NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.
0.014–0.025 in (0.35–0.65 mm)0.35–0.65 mm {0.014–0.025 in}
Factory HVAC service references (2005)
A/C refrigerant container storage limit (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Store the refrigerant container below 104 °F (40 °C).Store the refrigerant container below 40 °C {104 °F}.
A/C short-cycling pressure diagnosis (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
At clutch disengagement: 24 psi (167 kPa; 1.7 kgf/cm²) or lower — evacuate/recharge; 30 psi (206 kPa; 2.1 kgf/cm²) or higher — inspect thermoswitch.At clutch disengagement: 167 kPa (1.7 kgf/cm², 24 psi) or lower — evacuate/recharge; 206 kPa (2.1 kgf/cm², 30 psi) or higher — inspect thermoswitch.
A/C evacuation and vacuum retention (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.Run the vacuum pump for 15 minutes; both manifold gauges at –101 kPa {–760 mmHg, –29.9 inHg}. Close all manifold valves, stop the pump and wait about 5 minutes; the low-side reading must remain unchanged.
A/C refrigerant recovery equipment (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Recover R-134a with service equipment certified to SAE J2210; connect the recovery/recycling/recharging device and follow its manufacturer’s instructions.Recover R-134a with service equipment certified to SAE J2210; connect the recovery/recycling/recharging device and follow its manufacturer’s instructions.
A/C refrigerant joint preparation (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Oil the O-rings with compressor oil; start the joint nut or bolt by hand, then tighten to that joint’s specified torque. Use a spanner with the torque wrench on nut joints.Oil the O-rings with compressor oil; start the joint nut or bolt by hand, then tighten to that joint’s specified torque. Use a spanner with the torque wrench on nut joints.
A/C magnetic clutch clearance and shims (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Clearance 0.008–0.017 in (0.20–0.45 mm); shim choices 0.008 in (0.2 mm) and 0.02 in (0.5 mm).Clearance 0.20–0.45 mm {0.008–0.017 in}; shim choices 0.2 mm {0.008 in} and 0.5 mm {0.02 in}.
A/C panel switch continuity and LED (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
A–B: OFF open, ON continuity. With C at battery positive and A grounded, the indicator LED illuminates when switched ON.A–B: OFF open, ON continuity. With C at battery positive and A grounded, the indicator LED illuminates when switched ON.
Airflow defroster-mode switch continuity (2004–2005)
NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
Across the two contacts A–B: VENT, BI-LEVEL and HEAT open; HEAT/DEF and DEFROSTER continuity.Across the two contacts A–B: VENT, BI-LEVEL and HEAT open; HEAT/DEF and DEFROSTER continuity.
Factory air conditioning pressure inspection (1990)
Original A/C running refrigerant pressures (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Low side: 21–43 psi (147–294 kPa; 1.5–3.0 kg/cm²). High side: 1,177–1,171–235 psi (619 kPa; 12.0–16.5 kg/cm²).Low side: 147–294 kPa (1.5–3.0 kg/cm², 21–43 psi). High side: 1,177–1,619 kPa (12.0–16.5 kg/cm², 171–235 psi).
Heater temperature blend control-wire adjustment (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Set the temperature blend lever to MAX-HOT; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.Set the temperature blend lever to MAX-HOT; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.
Heater blower-motor connected feed voltage (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Ignition ON and blower switch in fourth position: blue (L) motor feed 12 V relative to body ground.Ignition ON and blower switch in fourth position: blue (L) motor feed 12 V relative to body ground.
Heater blower-resistor connected voltage checks (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Ignition ON, blower and A/C OFF: separate single-contact blue/red (L/R) resistor lead and four-contact plug wires L/W, L/R, L/G and L/Y each 12 V to body ground.Ignition ON, blower and A/C OFF: separate single-contact blue/red (L/R) resistor lead and four-contact plug wires L/W, L/R, L/G and L/Y each 12 V to body ground.
Heater blower-switch connected voltage checks (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Ignition ON, blower in fourth position: black (B) switch ground 0 V. Then blower and A/C OFF: switch L/W, L/R, L/G and L/Y each 12 V to body ground.Ignition ON, blower in fourth position: black (B) switch ground 0 V. Then blower and A/C OFF: switch L/W, L/R, L/G and L/Y each 12 V to body ground.
A/C magnetic-clutch connected feed voltage (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Engine idling, A/C and blower ON: black/red (B/R) magnetic-clutch connector feed 12 V to body ground.Engine idling, A/C and blower ON: black/red (B/R) magnetic-clutch connector feed 12 V to body ground.
A/C condenser-fan connected voltage checks (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
During the original A/C condenser-fan request: black/blue (B/L) fan feed 12 V and black (B) ground 0 V relative to body ground.During the original A/C condenser-fan request: black/blue (B/L) fan feed 12 V and black (B) ground 0 V relative to body ground.
Original A/C refrigerant sight-glass indications (1990–1991)
NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
Bubbles during operation indicate insufficient refrigerant; no bubbles can mean correct charge or excess. Immediately after A/C is switched OFF, continued clarity indicates excess, while foaming followed by clarity indicates the proper amount.Bubbles during operation indicate insufficient refrigerant; no bubbles can mean correct charge or excess. Immediately after A/C is switched OFF, continued clarity indicates excess, while foaming followed by clarity indicates the proper amount.
Heater temperature blend control-wire adjustment (1992–1993)
NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
Set the temperature blend lever to maximum hot; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.Set the temperature blend lever to maximum hot; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.
A/C refrigerant type (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Use only R-134a for the original factory A/C system.Use only R-134a for the original factory A/C system.
A/C refrigerant container storage limit (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Store the refrigerant container below 104 °F (40 °C).Store the refrigerant container below 40 °C {104 °F}.
A/C compressor oil type and handling (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Use only DENSO OIL9; cap oil and opened refrigerant components immediately against moisture.Use only DENSO OIL9; cap oil and opened refrigerant components immediately against moisture.
Heater air intake wire adjustment (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Set REC/FRESH lever and air intake link to REC; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.Set REC/FRESH lever and air intake link to REC; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.
Heater air mix wire adjustment (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Set temperature control dial and air mix link to MAX HOT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.Set temperature control dial and air mix link to MAX HOT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.
Heater airflow mode wire adjustment (1999–2000)
NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
Set airflow mode control dial and airflow mode link to VENT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.Set airflow mode control dial and airflow mode link to VENT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.
A/C magnetic clutch operation check (2001–2004)
NB 2001–2004 (BP-Z3) — 2002 applicability is supported by matching text in publication 1719-1U-01G; 2001 follows the owner-approved early-NB2 carry-over policy and is not an independently verified year.
With the clutch connector disconnected, apply battery positive to clutch terminal A and ground the compressor body; the magnetic clutch must operate.With the clutch connector disconnected, apply battery positive to clutch terminal A and ground the compressor body; the magnetic clutch must operate.
Additional 1994 service specifications
A/C drive belt tension — new belt (NA 1.8)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
110–132 lbf (490–588 N; 50.0–60.0 kgf)490–588 N {50.0–60.0 kgf, 110–132 lbf}
A/C drive belt deflection — new belt (NA 1.8)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
0.31–0.35 in (8.0–9.0 mm) under 22 lbf (98 N; 10 kgf)8.0–9.0 mm {0.31–0.35 in} under 98 N {10 kgf, 22 lbf}
A/C drive belt tension — used belt (NA 1.8)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
95–110 lbf (422–490 N; 43.0–50.0 kgf)422–490 N {43.0–50.0 kgf, 95–110 lbf}
A/C drive belt deflection — used belt (NA 1.8)
NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.
0.35–0.39 in (9.0–10.0 mm) under 22 lbf (98 N; 10 kgf)9.0–10.0 mm {0.35–0.39 in} under 98 N {10 kgf, 22 lbf}