A/C internal expansion-valve outlet pipe fitting (1990–1991)

22–25 ft·lb29–34 N·m29–34 N·m22–25 ft·lb
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Expansion-valve outlet connection to the evaporator inside the removed cooling-unit casing, separate from the external cooling-unit outlet. Diagnose the system before replacing the valve. Remove the evaporator and expansion valve together and release the sensing capillary tube from the outlet pipe before removing the valve. For the original factory R-12 system; converted systems are outside this specification. Recover refrigerant with suitable recovery equipment before opening the system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting; keep oil off the fitting nuts. Evacuate, charge and leak-test after repair.

Applies to
  • NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
  • Verified in: 1990 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • Page U–33 (PDF p.776) · Printed value & notes
    Part no. 1193-10-89C
    Page U–33 (PDF p.776)
    22–25 ft·lb (29–34 N·m)
    Printed: “Outlet pipe: 29—34 N·m (3.0—3.5 m-kg, 22—25 ft-lb)”
  • Page U–32 (PDF p.775) · Printed value & notes
    Part no. 1193-10-89C
    Page U–32 (PDF p.775)