Showing specs for all NA & NB Miatas

A/C internal expansion-valve inlet pipe fitting (1990–1991)

9–11 ft·lb12–15 N·m12–15 N·m9–11 ft·lb
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Inlet connection at the expansion valve inside the removed cooling-unit casing, separate from the external cooling-unit inlet. Diagnose the system before replacing the valve. Remove the evaporator and expansion valve together, disconnect the inlet/outlet pipes and release the sensing capillary tube from the outlet pipe before removing the valve. For the original factory R-12 system; converted systems are outside this specification. Recover refrigerant with suitable recovery equipment before opening the system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting; keep oil off the fitting nuts. Evacuate, charge and leak-test after repair.

Applies to
  • NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
  • Verified in: 1990 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • Page U–33 (PDF p.776) · Printed value & notes
    Part no. 1193-10-89C
    Page U–33 (PDF p.776)
    9–11 ft·lb (12–15 N·m)
    Printed: “Inlet pipe: 12—15 N·m (1.2—1.5 m-kg, 8.7—11 ft-lb)”
  • Page U–32 (PDF p.775) · Printed value & notes
    Part no. 1193-10-89C
    Page U–32 (PDF p.775)
    Printed: “Immediately plug all open fittings to keep moisture out of the system. Apply clean compressor oil to the O-rings before connecting the fittings. Do not apply compressor oil to the fitting nuts.”