A/C inline rigid-pipe to compressor-hose unions (1990–1991)
The two straight inline union nuts joining the rigid refrigerant pipes from the condenser/receiver-drier to the flexible compressor hoses. Both are identified as location 1 in the factory line drawing. These are separate from the hose ends at the compressor and the bulkhead cooling-unit fittings. For the original factory R-12 system; converted systems are outside this specification. Recover refrigerant with suitable recovery equipment before opening the system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting; keep oil off the fitting nuts. Evacuate, charge and leak-test after repair.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page U–37 (PDF p.780) · Printed value & notes
Part no. 1193-10-89CPage U–37 (PDF p.780)7–14 ft·lb (9.8–20 N·m)Printed: “① 9.8—20 N·m (1.0—2.0 m-kg, 7.2—14 ft-lb)”Page U–32 (PDF p.775) · Printed value & notes
Part no. 1193-10-89CPage U–32 (PDF p.775)Printed: “Immediately plug all open fittings to keep moisture out of the system. Apply clean compressor oil to the O-rings before connecting the fittings. Do not apply compressor oil to the fitting nuts.”
Related torque specs
- A/C external cooling-unit inlet pipe fitting (1990–1991)
- A/C external cooling-unit outlet pipe fitting (1990–1991)
- A/C internal expansion-valve inlet pipe fitting (1990–1991)
- A/C internal expansion-valve outlet pipe fitting (1990–1991)
- A/C receiver/drier inlet and outlet pipe fittings (1990–1991)
- A/C condenser inlet pipe fitting (1990–1991)
- A/C condenser outlet pipe fitting (1990–1991)
- A/C compressor inlet and outlet hose fittings (1990–1991)