Updated specs are available.
A/C condenser outlet pipe fitting (1990–1991)
This spec doesn't apply to the car you selected.
Not yet checked against the factory manual for your car's year. It's verified in the 1990 Mazda MX-5 Miata Workshop Manual; later manuals may differ.
7–14 ft·lb9.8–20 N·m9.8–20 N·m7–14 ft·lb
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure
Upper condenser outlet pipe union leading to the receiver/drier, one of the location-1 fittings in the factory line drawing. The lower inlet is location 2 and uses a different torque. For the original factory R-12 system; converted systems are outside this specification. Recover refrigerant with suitable recovery equipment before opening the system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting; keep oil off the fitting nuts. Evacuate, charge and leak-test after repair.
Applies to
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page U–37 (PDF p.780) · Printed value & notes
Part no. 1193-10-89CPage U–37 (PDF p.780)7–14 ft·lb (9.8–20 N·m)Printed: “① 9.8—20 N·m (1.0—2.0 m-kg, 7.2—14 ft-lb)”Page U–32 (PDF p.775) · Printed value & notes
Part no. 1193-10-89CPage U–32 (PDF p.775)Printed: “Immediately plug all open fittings to keep moisture out of the system. Apply clean compressor oil to the O-rings before connecting the fittings. Do not apply compressor oil to the fitting nuts.”
Related torque specs
- A/C external cooling-unit inlet pipe fitting (1990–1991)
- A/C external cooling-unit outlet pipe fitting (1990–1991)
- A/C internal expansion-valve inlet pipe fitting (1990–1991)
- A/C internal expansion-valve outlet pipe fitting (1990–1991)
- A/C receiver/drier inlet and outlet pipe fittings (1990–1991)
- A/C condenser inlet pipe fitting (1990–1991)
- A/C inline rigid-pipe to compressor-hose unions (1990–1991)
- A/C compressor inlet and outlet hose fittings (1990–1991)