Heater blower-resistor connected voltage checks (1990–1991)
Ignition ON, blower and A/C OFF: separate single-contact blue/red (L/R) resistor lead and four-contact plug wires L/W, L/R, L/G and L/Y each 12 V to body ground.Ignition ON, blower and A/C OFF: separate single-contact blue/red (L/R) resistor lead and four-contact plug wires L/W, L/R, L/G and L/Y each 12 V to body ground.
Use a DC voltmeter with a range of at least 15 V, positive probe at the named connected terminal wire and negative probe at body ground. Perform only after the breaker and motor-feed steps pass. Leave the resistor connectors connected. Check the single-contact L/R first, then the four-contact L/W, L/R, L/G and L/Y in that order. A 0 V single-contact input directs blower-motor replacement in this diagnostic branch; a 0 V subsequent tap after the preceding checks pass directs resistor-assembly replacement. Distinguish the separate L/R common lead from the L/R tap in the four-contact plug. These are powered connected-circuit checks, separate from isolated resistor continuity.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page U–6 (PDF p.749) · Printed value & notes
Part no. 1193-10-89CPage U–6 (PDF p.749)Printed: “A voltmeter with a range of 15V or more must be used. It is used by connecting the positive (+) probe (red lead) to the point where voltage is to be measured and connecting the negative (−) probe (black lead) to a body ground.”Page U–8 (PDF p.751) · Printed value & notes
Part no. 1193-10-89CPage U–8 (PDF p.751)Printed: “Turn the ignition switch ON. Turn the blower switch and A/C switch OFF. Measure the voltage at the terminal-wires of the resistor as- sembly. (L/R) (1-pin connector) 12V (L/W) 12V (L/R) (4-pin connector) 12V (L/G) 12V (L/Y) 12V”
Related service specs
- Original A/C running refrigerant pressures (1990–1991)
- Heater temperature blend control-wire adjustment (1990–1991)
- Heater blower-motor connected feed voltage (1990–1991)
- Heater blower-switch connected voltage checks (1990–1991)
- A/C magnetic-clutch connected feed voltage (1990–1991)
- A/C condenser-fan connected voltage checks (1990–1991)
- Original A/C refrigerant sight-glass indications (1990–1991)
- Heater temperature blend control-wire adjustment (1992–1993)