Heater blower-switch connected voltage checks (1990–1991)
Ignition ON, blower in fourth position: black (B) switch ground 0 V. Then blower and A/C OFF: switch L/W, L/R, L/G and L/Y each 12 V to body ground.Ignition ON, blower in fourth position: black (B) switch ground 0 V. Then blower and A/C OFF: switch L/W, L/R, L/G and L/Y each 12 V to body ground.
Use a DC voltmeter with a range of at least 15 V, positive probe at the named connected terminal wire and negative probe at body ground. Follow the breaker, motor-feed and resistor steps first; keep the switch connector connected. At fourth blower position, 12 V on B directs repair of the switch-to-body-ground harness. With that ground check passed, turn blower and A/C OFF and check L/W, L/R, L/G and L/Y in order. A 0 V speed wire directs repair of its resistor-to-switch harness. If all four read 12 V in this branch, the flow directs switch replacement. The powered tests use different switch positions; do not combine them into one test state or an isolated continuity test.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page U–6 (PDF p.749) · Printed value & notes
Part no. 1193-10-89CPage U–6 (PDF p.749)Printed: “A voltmeter with a range of 15V or more must be used. It is used by connecting the positive (+) probe (red lead) to the point where voltage is to be measured and connecting the negative (−) probe (black lead) to a body ground.”Page U–8 (PDF p.751) · Printed value & notes
Part no. 1193-10-89CPage U–8 (PDF p.751)Printed: “Turn the ignition switch ON. Turn the blower switch to the fourth position. (B) 0V 12V Repair wire harness (Blower switch—Body ground) Turn the ignition switch ON. Turn the blower switch and A/C switch OFF. (L/W) 12V (L/R) 12V (L/G) 12V (L/Y) 12V”
Related service specs
- Original A/C running refrigerant pressures (1990–1991)
- Heater temperature blend control-wire adjustment (1990–1991)
- Heater blower-motor connected feed voltage (1990–1991)
- Heater blower-resistor connected voltage checks (1990–1991)
- A/C magnetic-clutch connected feed voltage (1990–1991)
- A/C condenser-fan connected voltage checks (1990–1991)
- Original A/C refrigerant sight-glass indications (1990–1991)
- Heater temperature blend control-wire adjustment (1992–1993)