Showing specs for all NA & NB Miatas

Heater blower-motor connected feed voltage (1990–1991)

Ignition ON and blower switch in fourth position: blue (L) motor feed 12 V relative to body ground.Ignition ON and blower switch in fourth position: blue (L) motor feed 12 V relative to body ground.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Use a DC voltmeter with a range of at least 15 V, positive probe at the named connected terminal wire and negative probe at body ground. Follow the original blower-does-not-operate sequence, checking the HEATER circuit breaker and repairing a short before resetting a tripped breaker. Keep the blower connector connected for this voltage check. A 0 V feed directs repair of the breaker-to-motor harness; 12 V permits the subsequent resistor checks. The factory prints 12 V without a tolerance; it is not a disconnected motor resistance or direct battery test.

Applies to
  • NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
  • Verified in: 1990 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • Page U–6 (PDF p.749) · Printed value & notes
    Part no. 1193-10-89C
    Page U–6 (PDF p.749)
    Printed: “A voltmeter with a range of 15V or more must be used. It is used by connecting the positive (+) probe (red lead) to the point where voltage is to be measured and connecting the negative (−) probe (black lead) to a body ground.”
  • Page U–7 (PDF p.750) · Printed value & notes
    Part no. 1193-10-89C
    Page U–7 (PDF p.750)
    Printed: “Turn the ignition switch ON. Turn the blower switch to the fourth position. Measure the voltage at terminal-wire (L) of the blower mo- tor connector. (L) 12V 0V Repair wire harness (Circuit breaker—Blower motor)”