Original A/C running refrigerant pressures (1990–1991)
Low side: 21–43 psi (147–294 kPa; 1.5–3.0 kg/cm²). High side: 1,177–1,171–235 psi (619 kPa; 12.0–16.5 kg/cm²).Low side: 147–294 kPa (1.5–3.0 kg/cm², 21–43 psi). High side: 1,177–1,619 kPa (12.0–16.5 kg/cm², 171–235 psi).
For the original factory A/C system. Connect the manifold gauge set with both hand valves closed, low hose to low-pressure pipe fitting and high hose to high-pressure pipe fitting; tighten hose nuts by hand only. Operate the engine at 1,500 rpm with the air conditioner set to maximum cooling, then measure both sides. These are running pressures, not engine-off static pressure or refrigerant charging quantity; the source does not establish these ranges for a converted system.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1990 Mazda MX-5 Miata Workshop Manual
Sources (3)
View 3 source citations
Page TD–12 (PDF p.798) · Printed value & notes
Part no. 1193-10-89CPage TD–12 (PDF p.798)Printed: “Refrigerant normal pressure kPa (kg/cm², psi) Low pressure: 147—294 (1.5—3.0, 21—43) High pressure: 1,177—1,619 (12.0—16.5, 171—235)”Page U–28; U–31 (PDF pp. 771, 774) · Printed value & notes
Part no. 1193-10-89CPage U–28; U–31 (PDF pp. 771, 774)Printed: “Close both hand valves of the manifold gauge set. Tighten the hose nuts by hand only. Operate the engine at 1,500 rpm and set the air conditioner to maximum cooling. Normal pressure Low-pressure side: 147—294 kPa (1.5—3.0 kg/cm², 21—43 psi) High-pressure side: 1,177—1,619 kPa (12.0—16.5 kg/cm², 171—235 psi)”Page A–5; A–8 (PDF pp. 24, 27) · Printed value & notes
Part no. 1193-10-89CPage A–5; A–8 (PDF pp. 24, 27)Printed: “Refrigerant pressure: Low pressure: 147—294 kPa (1.5—3.0 kg/cm², 21—43 psi) High pressure: 1,177—1,619 kPa (12.0—16.5 kg/cm², 171—235 psi)”
Related service specs
- Heater temperature blend control-wire adjustment (1990–1991)
- Heater blower-motor connected feed voltage (1990–1991)
- Heater blower-resistor connected voltage checks (1990–1991)
- Heater blower-switch connected voltage checks (1990–1991)
- A/C magnetic-clutch connected feed voltage (1990–1991)
- A/C condenser-fan connected voltage checks (1990–1991)
- Original A/C refrigerant sight-glass indications (1990–1991)
- Heater temperature blend control-wire adjustment (1992–1993)