Showing specs for all NA & NB Miatas

Heater temperature blend control-wire adjustment (1992–1993)

Set the temperature blend lever to maximum hot; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.Set the temperature blend lever to maximum hot; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

For reconnecting the original mechanical heater temperature blend wire. Select maximum hot at the control panel, then connect and clamp the wire with the heater shutter lever at the MAXIMUM HOT end shown in the factory U–25 view. Right refers to that illustrated lever view. After installation, move the temperature blend control through its full HOT-to-COLD stroke and verify secure wire attachment and full travel. This is separate from the airflow-mode and REC–FRESH cable settings.

Applies to
  • NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
  • Verified in: 1992 Mazda MX-5 Miata Workshop Manual

Sources (1)

View 1 source citations
  • 1992 Mazda MX-5 Miata Workshop ManualTier 1
    Page U–25 (PDF p. 1017) · Printed value & notes
    Part no. 1271-10-91G (9999-95-0428-92)
    Page U–25 (PDF p. 1017)
    Printed: “Set the temperature blend lever to maximum hot position. Connect and clamp the wire with the shutter lever on the heater unit all the way to the right. After installation, move the temperature blend lever to be sure the wire is securely attached and that it moves the full stroke from HOT to COLD.”