Heater air mix wire adjustment (1999–2000)
Set temperature control dial and air mix link to MAX HOT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.Set temperature control dial and air mix link to MAX HOT; locate link with screwdriver in its set hole, connect and clamp wire, then verify full control travel.
For reconnecting the original1999 heater-control air mix wire. Before adjustment reinstall the heater control with wires routed as shown in the factory installation drawing, connect its plugs and seat the retaining clips. Select MAX HOT at the temperature control dial, move the corresponding unit link in the factory arrow direction to its matching MAX HOT position and locate it with a screwdriver through its set hole. Connect the wire end to that link and secure its outer cable in the wire clamp. Verify that the control moves through its full stroke after adjustment. Use the specific air mix linkage and set hole; the other two control wires have different starting positions. Battery negative is disconnected during heater-control removal and reconnected after installation/adjustment.
- NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
- Verified in: 1999 Mazda MX-5 Miata Workshop Manual
Sources (1)
View 1 source citations
Page 07–40–7;07–40–9 (PDF pp.575,577) · Printed value & notes
Page 07–40–7;07–40–9 (PDF pp.575,577)Printed: “Set the temperature control dial at MAX HOT. Set the air mix link to MAX HOT in the direction of the arrow and insert a screwdriver into the set hole. Connect the air mix wire to the air mix link. Clamp the air mix wire to wire clamp. Verify that the temperature control dial moves its full stroke.”
Related service specs
- Original A/C running refrigerant pressures (1990–1991)
- Heater temperature blend control-wire adjustment (1990–1991)
- Heater blower-motor connected feed voltage (1990–1991)
- Heater blower-resistor connected voltage checks (1990–1991)
- Heater blower-switch connected voltage checks (1990–1991)
- A/C magnetic-clutch connected feed voltage (1990–1991)
- A/C condenser-fan connected voltage checks (1990–1991)
- Original A/C refrigerant sight-glass indications (1990–1991)