Showing specs for all NA & NB Miatas

A/C refrigerant recovery equipment (2004–2005)

Recover R-134a with service equipment certified to SAE J2210; connect the recovery/recycling/recharging device and follow its manufacturer’s instructions.Recover R-134a with service equipment certified to SAE J2210; connect the recovery/recycling/recharging device and follow its manufacturer’s instructions.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Avoid breathing refrigerant or lubricant vapor. Ventilate the work area after an accidental discharge before resuming service. The factory instruction requires recovery equipment; it does not authorize venting refrigerant or using compressed air for pressure/leak testing.

Applies to
  • NB 2005 (BP-Z3/BP-Z3-TURBO)
  • NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
  • Verified in: 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)

Sources (1)

View 1 source citations
  • 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Refrigerant Recovery (PDF p.1740); Service Warnings (PDF p.1730) · Printed value & notes
    Page Refrigerant Recovery (PDF p.1740); Service Warnings (PDF p.1730)
    Printed: “use service equipment certified to meet the requirements of SAE J2210 (R-134a recycling equipment) when draining R-134a from the air conditioning system. If accidental system discharge occurs, ventilate work area before resuming service. Connect an R-134a recovery/recycling/recharging device to the vehicle and follow the device manufacturer's instructions.”