Showing specs for all NA & NB Miatas

A/C short-cycling pressure diagnosis (2004–2005)

At clutch disengagement: 24 psi (167 kPa; 1.7 kgf/cm²) or lower — evacuate/recharge; 30 psi (206 kPa; 2.1 kgf/cm²) or higher — inspect thermoswitch.At clutch disengagement: 167 kPa (1.7 kgf/cm², 24 psi) or lower — evacuate/recharge; 206 kPa (2.1 kgf/cm², 30 psi) or higher — inspect thermoswitch.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

For insufficient cooling with the compressor short-cycling, install manifold gauges and run engine at 2,000 rpm, A/C ON, fan at 4th and intake lever at REC. Observe the low-side gauge exactly when the magnetic clutch disengages. The two values select diagnostic branches; they are not an operating-pressure range or charge-mass measurement. The source gives no branch between 167 and 206 kPa. Evacuating/recharging means using appropriate recovery/service equipment and the specified refrigerant mass.

Applies to
  • NB 2005 (BP-Z3/BP-Z3-TURBO)
  • NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
  • Verified in: 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)

Sources (1)

View 1 source citations
  • 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Refrigerant Charge Check (PDF p.1736) · Printed value & notes
    Page Refrigerant Charge Check (PDF p.1736)
    Printed: “Start the engine and run it at a constant 2,000 rpm. Turn the A/C switch on and set the fan switch at 4th. Set the REC/FRESH lever to REC. If the A/C compressor is short-cycling, note the low-pressure side reading at which the magnetic clutch kicks out. If the pressure is 167 kPa {1.7 kgf/cm², 24 psi} or lower, evacuate then recharge the refrigerant system with the proper amount of refrigerant. If the pressure is 206 kPa {2.1 kgf/cm², 30 psi} or higher, inspect the thermoswitch.”