Not yet checked against the factory manual for your car's year. It's verified in the 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual; later manuals may differ.
Store the R-12 refrigerant container below 125.6 °F (52 °C); do not expose it to high heat.Store the R-12 refrigerant container below 52°C (125.6°F); do not expose it to high heat.
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure
This limit concerns the pressurized refrigerant supply container used with the original R-12 system, not vehicle operating temperature, refrigerant pressure or a water-bath charging temperature. Follow the container instructions and keep it away from flames; the source warns that R-12 contacting flame produces toxic phosgene.
Applies to
- NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page U–27 (PDF p. 770) · Printed value & notes
Part no. 1193-10-89CPage U–27 (PDF p. 770)Printed: “The R-12 container is a highly pressurized vessel. Never subject it to high heat, and be sure that the temperature where it is stored is below 52°C (125.6°F).”Visually checked against the original 1990 factory page, including printed units and component/test context.- 1992 Mazda MX-5 Miata Workshop ManualTier 1
Page U–27 (PDF p. 1019) · Printed value & notes
Part no. 1271-10-91G (9999-95-0428-92)Page U–27 (PDF p. 1019)Printed: “The R-12 container is a highly pressurized vessel. Never subject it to high heat, and be sure that the temperature where it is stored is below 52°C (125.6°F).”
Related service specs
- Heater blower-speed switch continuity (1990–1993)
- Heater blower-motor supply voltage (1992–1993)
- Heater blower-resistor connected voltage checks (1992–1993)
- Heater blower-switch connected voltage checks (1992–1993)
- A/C magnetic-clutch feed voltage (1992–1993)
- A/C condenser-fan connected voltage checks (1992–1993)
- A/C insufficient-cooling pressure check at 2,000 rpm (1990–1993)
- A/C sight-glass charge observation (1992–1993)