Showing specs for all NA & NB Miatas

A/C internal expansion-valve inlet pipe fitting (1992–1993)

9–11 ft·lb12–15 N·m12–15 N·m9–11 ft·lb
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

For the inlet pipe connection to the expansion valve inside the removed evaporator cooling-unit casing. This is separate from the external cooling-unit inlet connection, which has its own torque. Remove the evaporator and expansion valve together to service the valve, and diagnose the system before replacing it. Recover refrigerant with proper recovery equipment before opening the original R-12 system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting, and keep oil off the fitting nuts. Evacuate, charge and leak-test after repair.

Applies to
  • NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
  • Verified in: 1992 Mazda MX-5 Miata Workshop Manual