A/C evaporator thermoswitch continuity (1990–1993)
Above 32 °F (0 °C): continuity; below 32 °F (0 °C): no continuity.Above 0°C (32°F): continuity; below 0°C (32°F): no continuity.
For the removed-switch inspection, immerse the sensing bulb in an ice-water container and check continuity between the two switch terminals while monitoring sensing-bulb temperature. The source specifies behavior above and below zero, with no acceptance state exactly at zero. On vehicle, remove glove box, idle engine with A/C OFF and blower on highest for a few minutes; then turn blower OFF, stop engine, unplug thermoswitch and verify continuity. Cold evaporator below zero intentionally opens contacts. Replace thermoswitch if behavior is incorrect.
- NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page U–34 (PDF p. 777) · Printed value & notes
Part no. 1193-10-89CPage U–34 (PDF p. 777)Printed: “Terminals Temperature Continuity a—b Above 0°C (32°F) Yes Below 0°C (32°F) No”Visually checked against the original 1990 factory page, including printed units and component/test context.- 1992 Mazda MX-5 Miata Workshop ManualTier 1
Page U–36 (PDF p. 1028) · Printed value & notes
Part no. 1271-10-91G (9999-95-0428-92)Page U–36 (PDF p. 1028)Printed: “Terminals Temperature Continuity a—b Above 0°C (32°F) Yes Below 0°C (32°F) No”
Related service specs
- Heater blower-speed switch continuity (1990–1993)
- Heater blower-motor supply voltage (1992–1993)
- Heater blower-resistor connected voltage checks (1992–1993)
- Heater blower-switch connected voltage checks (1992–1993)
- A/C magnetic-clutch feed voltage (1992–1993)
- A/C condenser-fan connected voltage checks (1992–1993)
- A/C insufficient-cooling pressure check at 2,000 rpm (1990–1993)
- A/C sight-glass charge observation (1992–1993)