Showing specs for all NA & NB Miatas

A/C refrigerant container storage temperature limit (2001–2004)

Store the refrigerant container below 104 °F (40 °C).Store the refrigerant container below 40 °C {104 °F}.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Applies to storage of the pressurized refrigerant container used for servicing the original R134a system. This is a container storage limit, rather than an ambient-temperature condition for a vehicle pressure or cooling-performance test.

Applies to
  • NB 2003–2004 (BP-Z3)
  • NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
  • Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)

Sources (3)

View 3 source citations
  • Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
    Page 07–10–1 (PDF p. 738) · Printed value & notes
    Part no. 1719-1U-01G
    Page 07–10–1 (PDF p. 738)
    Printed: “Store the refrigerant at temperatures below 40 °C {104 °F}.”
    Visually checked against the original page. Early-NB2 mechanical use authorized by owner; exact full-document edition and market remain unconfirmed.
  • 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Refrigerant System Service Warnings (PDF pp. 1602, 1603) · Printed value & notes
    Page Refrigerant System Service Warnings (PDF pp. 1602, 1603)
    Printed: “The refrigerant container is highly pressurized. If it is subjected to high heat, it could explode, scattering metal fragments and liquid refrigerant that can seriously injure you. Store the refrigerant at temperatures below 40 °C {104 °F}.”
  • 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Refrigerant System Service Warnings (PDF pp. 1598, 1599) · Printed value & notes
    Page Refrigerant System Service Warnings (PDF pp. 1598, 1599)
    Printed: “The refrigerant container is highly pressurized. If it is subjected to high heat, it could explode, scattering metal fragments and liquid refrigerant that can seriously injure you. Store the refrigerant at temperatures below 40 °C {104 °F}.”