A/C internal expansion-valve outlet pipe fitting (1992–1993)

22–25 ft·lb29–34 N·m29–34 N·m22–25 ft·lb
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

For the expansion-valve outlet connection to the evaporator inside the removed cooling-unit casing. This is separate from the external cooling-unit outlet fitting. During valve replacement, release the sensing capillary tube from the outlet pipe before removing the valve. Recover refrigerant with proper recovery equipment before opening the original R-12 system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting, and keep oil off the fitting nuts. Evacuate, charge and leak-test after repair.

Applies to
  • NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
  • Verified in: 1992 Mazda MX-5 Miata Workshop Manual