A/C preliminary refrigerant leak-test pressure (2001–2004)
After evacuation and the vacuum retention check, admit refrigerant through the low-side manifold valve to a low-side reading of 14 psi (0.1 MPa; 1 kgf/cm²); close the valve and check pipe/hose joints with a gas leak tester.After evacuation and the vacuum retention check, admit refrigerant through the low-side manifold valve to a low-side reading of 0.1 MPa {1 kgf/cm², 14 psi}; close the valve and check pipe/hose joints with a gas leak tester.
Original R-134a system. Complete the separate evacuation/retention procedure first, leaving the engine stopped and the high-side manifold valve closed. Open the tank valve and record the tank weight before opening the low-side manifold valve. At the stated low-side gauge reading, close that valve and use the detector on cooler pipe/hose joints. Retighten a loose leaking joint and retest. If it still leaks, recover the refrigerant, repair the joint and repeat evacuation before restarting charging. Only proceed to the staged mass charge once no leaks are found. This is a preliminary leak-test pressure, not a running-pressure criterion or full-charge indication. Never open the high-side manifold valve while the engine is running.
- NB 2003 (BP-Z3)
- NB 2004 (BP-Z3)
- NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.
- Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)
Sources (3)
View 3 source citations
- Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
Page 07–10–5 (PDF p. 742) · Printed value & notes
Part no. 1719-1U-01GPage 07–10–5 (PDF p. 742)Printed: “When the low-pressure side reading increases to 0.1 MPa {1 kgf/cm2, 14 psi}, close the low-pressure side valve of the manifold gauge. Check for leaks from the cooler pipe/hose connections using a gas leak tester.”Visually checked against the original page. Early-NB2 mechanical use authorized by owner; exact full-document edition and market remain unconfirmed. - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Refrigerant charging (PDF p. 1615) · Printed value & notes
Page Refrigerant charging (PDF p. 1615)Printed: “When the low pressure side reading increases to 0.1 MPa {1 kgf/cm², 14 psi}, close the low pressure side valve of the manifold gauge. Check for leaks from the cooler pipe/hose connections using a gas leak tester.” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Refrigerant charging (PDF p. 1611) · Printed value & notes
Page Refrigerant charging (PDF p. 1611)Printed: “When the low pressure side reading increases to 0.1 MPa {1 kgf/cm², 14 psi}, close the low pressure side valve of the manifold gauge. Check for leaks from the cooler pipe/hose connections using a gas leak tester.”
Related service specs
- Heater blower-speed switch continuity (1990–1993)
- Heater blower-motor supply voltage (1992–1993)
- Heater blower-resistor connected voltage checks (1992–1993)
- Heater blower-switch connected voltage checks (1992–1993)
- A/C magnetic-clutch feed voltage (1992–1993)
- A/C condenser-fan connected voltage checks (1992–1993)
- A/C insufficient-cooling pressure check at 2,000 rpm (1990–1993)
- A/C sight-glass charge observation (1992–1993)