Showing specs for all NA & NB Miatas

Automatic TCM power and ground voltage reference (1999–2000)

AR: B+ constant. AS: 0 V ignition OFF ,B+ ON. AP: TCM ground,0 V constant.AR: B+ constant. AS: 0 V ignition OFF ,B+ ON. AP: TCM ground,0 V constant.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Factory TCM Terminal Voltage Chart reference data. Use the original labelled TCM terminal chart with confirmed connector identity and viewing direction; do not infer a connector face or pin position from an unlabeled sketch. Use TCM terminal AP for the negative meter lead as required by the factory note, rather than a general body-ground substitute. Turn ignition ON except for a row explicitly requiring OFF; keep each printed engine, selector and operating condition. Inspect related devices and wiring before condemning the TCM from an incorrect reading. These powered voltage checks are not isolated component resistance tests. The chart requires AP as the measurement reference for other terminals. Check AP-to-ground continuity as directed in the basic inspection with ignitionOFF and the connector disconnected; do not perform resistance checks on a powered circuit. AR is the battery supply; AS is the main-relay supply. A supply or ground fault requires its complete harness/power-circuit diagnostic, not automatic TCM replacement.

Applies to
  • NB 1999–2000 (BP-4W, 4AT) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual