Automatic TCM throttle voltage reference (1999–2000)

R(Vref): 0 V ignition OFF ,4.5–5.5 V ON. U(TVO): 0.3–1.0 V throttle closed,3.7–4.4 V wide open.R(Vref): 0 V ignition OFF ,4.5–5.5 V ON. U(TVO): 0.3–1.0 V throttle closed,3.7–4.4 V wide open.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Factory TCM Terminal Voltage Chart reference data. Use the original labelled TCM terminal chart with confirmed connector identity and viewing direction; do not infer a connector face or pin position from an unlabeled sketch. Use TCM terminal AP for the negative meter lead as required by the factory note, rather than a general body-ground substitute. Turn ignition ON except for a row explicitly requiring OFF; keep each printed engine, selector and operating condition. Inspect related devices and wiring before condemning the TCM from an incorrect reading. These powered voltage checks are not isolated component resistance tests. Measure the TCM TPS reference and output at their separate identified terminals. Retain both throttle positions. These terminal reference values differ in purpose and location from the PCM TP V scan-data ranges and from P1771/P1772 fault-trigger thresholds; do not substitute one window for another.

Applies to
  • NB 1999–2000 (BP-4W, 4AT) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual