Automatic TCM shift and lockup solenoid output voltage reference (1999–2000)

AN(shiftB),AO(TCC),AQ(shiftA): B+ with that solenoid ON,0 V OFF . In1st AQ/AN=B+ /0 V; 2nd=B+ /B+ ; 3rd=0 V/B+ ; 4th=0 V/0 V.AN(shiftB),AO(TCC),AQ(shiftA): B+ with that solenoid ON,0 V OFF . In1st AQ/AN=B+ /0 V; 2nd=B+ /B+ ; 3rd=0 V/B+ ; 4th=0 V/0 V.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Factory TCM Terminal Voltage Chart reference data. Use the original labelled TCM terminal chart with confirmed connector identity and viewing direction; do not infer a connector face or pin position from an unlabeled sketch. Use TCM terminal AP for the negative meter lead as required by the factory note, rather than a general body-ground substitute. Turn ignition ON except for a row explicitly requiring OFF; keep each printed engine, selector and operating condition. Inspect related devices and wiring before condemning the TCM from an incorrect reading. These powered voltage checks are not isolated component resistance tests. Identify TCM outputs AQ/AN/AO independently from transmission solenoid-connector letters. The diagnostic road check uses NGS at DLC2, TP V and VS PIDs, and the complete factory shift diagram to confirm actual gear and TCC conditions; do not infer road speeds from this electrical table. For no-move/no-creep checks the original specifies ignitionON and D (442 additionally2/1), AQ=B+ and AN=0V. The isolated harness check disconnects the solenoid connector and checks its harness B=B+,A=0V under the stated range condition; these are not contacts to power with a jumper. Follow complete connector/wiring,ground and mechanical-solenoid diagnostics before replacement.

Applies to
  • NB 1999–2000 (BP-4W, 4AT) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (2)

View 2 source citations
  • Page 05–13–18–19 (PDF pp. 495–496) · Printed value & notes
    Page 05–13–18–19 (PDF pp. 495–496)
    Printed: “AN Shift solenoid B Solenoid is on. B+ Solenoid is off. 0 AO Torque converter clutch solenoid valve Solenoid is on. B+ Solenoid is off. 0 AQ Shift solenoid A Solenoid is on. B+ Solenoid is off. 0”
  • Page 05–01–21 / 05–01–23–27 / 05–01–30 (PDF pp. 442, 444–448, 451) · Printed value & notes
    Page 05–01–21 / 05–01–23–27 / 05–01–30 (PDF pp. 442, 444–448, 451)
    Printed: “1GR TCM terminal AQ: B+ TCM terminal AN: 0 V 2GR TCM terminal AQ: B+ TCM terminal AN: B+ 3GR TCM terminal AQ: 0 V TCM terminal AN: B+ 4GR TCM terminal AQ: 0 V TCM terminal AN: 0 V Specification: B+ in TCC condition”