BARO/MAP circuit low/high voltage detection (2004 Mazdaspeed)
With intake-air temperature above 50 °F (10 °C), at PCM terminal 4AE: P0107 below 0.13 V; P0108 above 4.8 V.With intake-air temperature above 10°C {50°F}, at PCM terminal 4AE: P0107 below 0.13 V; P0108 above 4.8 V.
The intake-air temperature prerequisite applies to both voltage checks. The excerpt supplies no time delay or pressure-to-voltage calibration; do not use these fault thresholds as a boost-pressure limit. Describes the original PCM diagnostic detection logic, not a sensor calibration target, normal operating range or instruction to reproduce the fault. Use the complete factory DTC troubleshooting procedure to diagnose wiring, connectors and components; a stored code alone does not identify a failed part.
- NB 2004 (BP-Z3-TURBO, 6MT)
- Verified in: 2004 MAZDASPEED MX-5 Service Highlights (with normally aspirated BP comparisons)
Sources (1)
View 1 source citations
- 2004 MAZDASPEED MX-5 Service Highlights (with normally aspirated BP comparisons)Tier 1
Page 01–02–2 (PDF p. 8) · Printed value & notes
Part no. 9999-95-072F-04Page 01–02–2 (PDF p. 8)Printed: “P0107 BARO/MAP circuit low input PCM monitors input voltage from BARO/MAP sensor when monitoring conditions are met. If input voltage at PCM terminal 4AE is below 0.13 V, PCM determines that BARO/MAP sensor circuit is malfunctioning MONITORING CONDITION — IAT is above 10°C {50°F}. P0108 BARO/MAP circuit high input PCM monitors input voltage from BARO/MAP sensor when monitoring conditions are met. If input voltage at PCM terminal 4AE is above 4.8 V, PCM determines that BARO/MAP sensor circuit is malfunctioning. MONITORING CONDITION — IAT is above 10°C {50°F}.”
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)