Updated specs are available.
Battery post-charge voltage retention (2001–2004)
This spec doesn't apply to the car you selected.
Not yet checked against the factory manual for your car's year. It's verified in the 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition); later manuals may differ.
Above 12.4 V for more than 1 hour after rechargingAbove 12.4 V for more than 1 hour after recharging
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure
After recharging the factory battery, measure across its terminals and verify that it retains the specified voltage for more than one hour. Replace the battery if it fails. This is post-charge retention, separate from voltage under the 15-second load test.
Applies to
- NB 2003 (BP-Z3)
- NB 2004 (BP-Z3)
- NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
- Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)
Sources (5)
View 5 source citations
- Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
Page 01–17–3 (PDF p. 349) · Printed value & notes
Part no. 1719-1U-01GPage 01–17–3 (PDF p. 349)Printed: “After the battery has been recharged, measure the battery positive voltage and verify that the battery keeps specified voltage for more than 1 hour. Specification Above 12.4 V”Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned. - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Battery post-charge voltage retention (2003–2004) (PDF p. 785) · Printed value & notes
Page Battery post-charge voltage retention (2003–2004) (PDF p. 785)Printed: “Specification Above 12.4 V” - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Battery Recharging — post-charge duration (PDF p.785) · Printed value & notes
Page Battery Recharging — post-charge duration (PDF p.785)Printed: “After the battery has been recharged, measure the battery positive voltage and verify that the battery keeps specified voltage for more than 1 hour. If not as specified, replace the battery. Specification Above 12.4 V”Original duration corroborates the complete existing strict-above12.4V/morethan1hour criterion; not a charging-current instruction or loaded15s reading. - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Battery post-charge voltage retention (2003–2004) (PDF p. 814) · Printed value & notes
Page Battery post-charge voltage retention (2003–2004) (PDF p. 814)Printed: “Specification Above 12.4 V” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Battery Recharging — post-charge duration (PDF pp.813–814) · Printed value & notes
Page Battery Recharging — post-charge duration (PDF pp.813–814)Printed: “After the battery has been recharged, measure the battery positive voltage and verify that the battery keeps specified voltage for more than 1 hour. If not as specified, replace the battery. Specification Above 12.4 V”Full existing strict-above12.4V/morethan1hour postcharge criterion supported. This is distinct from initial>=12.4V screening and15s loadedvoltage. Existing applicability unchanged.
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)