Factory battery charging currents (2001–2004)
S46A24L(S), 32 Ah at 5-hour rate: slow charge 3.0–4.0 A; quick charge 20 A for no more than 30 min.S46A24L(S), 32 Ah at 5-hour rate: slow charge 3.0–4.0 A; quick charge 20 A for no more than 30 min.
For the specified factory battery only. Stop engine, turn all accessories off, disconnect negative cable first and install it last. Keep heat, flames and sparks away from hydrogen. Factory setup places battery in a pan with water about halfway up its case, keeping water off its top to control overheating. Never quick-charge beyond 30 minutes. A different replacement battery requires its own charging instructions.
- NB 2003 (BP-Z3)
- NB 2004 (BP-Z3)
- NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
- Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)
Sources (6)
View 6 source citations
- Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
Page 01–17–3 (PDF p. 349) · Printed value & notes
Part no. 1719-1U-01GPage 01–17–3 (PDF p. 349)Printed: “Do not quick charge for over 30 min as it will damage the battery. Battery type (5-hour rate) S46A24L(S)(32) Slow charge (A) 3.0—4.0 Quick charge (A)/(30 min) 20”Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned. - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Factory battery charging currents (2003–2004) (PDF p. 784) · Printed value & notes
Page Factory battery charging currents (2003–2004) (PDF p. 784)Printed: “Battery type (5 hour rate) Slow charge (A) Quick charge (A)/(30 min) S46A24L(S)(32) 3.0—4.0 20” - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Battery Recharging — required preparation (PDF p.784) · Printed value & notes
Page Battery Recharging — required preparation (PDF p.784)Printed: “When disconnecting the battery, remove the negative cable first and install it last turn all accessories off and stop the engine Do not quick charge for over 30 min as it will damage the battery. Place a battery in a pan of water to prevent it from overheating. The water level should come up about halfway on the battery. Keep water off the top of the battery.”Supports the complete existing factory S46A24L(S)(32) charging setup, hydrogen precautions and water-bath level. Slow3.0–4.0A and quick20A/30min remain restricted to that battery. - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Factory battery charging currents (2003–2004) (PDF p. 813) · Printed value & notes
Page Factory battery charging currents (2003–2004) (PDF p. 813)Printed: “Battery type (5 hour rate) Slow charge (A) Quick charge (A)/(30 min) S46A24L(S)(32) 3.0—4.0 20” - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Battery Recharging — required preparation (PDF p.813) · Printed value & notes
Page Battery Recharging — required preparation (PDF p.813)Printed: “When disconnecting the battery, remove the negative cable first and install it last turn all accessories off and stop the engine Do not quick charge for over 30 min as it will damage the battery. Place a battery in a pan of water to prevent it from overheating. The water level should come up about halfway on the battery. Keep water off the top of the battery.”Supports full current factory S46A24L(S)(32)charging setup and hydrogen precautions. Slow3.0–4.0A/quick20Amax30min remain restricted to stated factorybattery,notmodernreplacement instructions. - 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Engine Technical Data (PDF p.930) · Printed value & notes
Page Engine Technical Data (PDF p.930)Printed: “Battery Slow charge (A) Battery type (5 hour rate) S46A24L (S) (32) 3.0—4.0 Quick charge (A/30 min.) Battery type (5 hour rate) S46A24L (S) (32) 20”Originalactual2004tableagreescompletecurrentrecord. Listedfactorybatteryonly. Completecurrent813shutdown/accessoriesOFF/negativefirstandlast/hydrogenprecautions/waterbathandmaximum30minutesquickchargeretained. No modernbatterysettingsinferred. No applicability extension.
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)