Updated specs are available.
Factory starter nominal rated output (1990–1993)
This spec doesn't apply to the car you selected.
Not yet checked against the factory manual for your car's year. It's verified in the 1990 Mazda MX-5 Miata Workshop Manual; 1992 Mazda MX-5 Miata Workshop Manual; later manuals may differ.
12 V, 0.95 kW12 V, 0.95 kW
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure
Factory nominal rating of the original direct-drive starter. This is separate from the no-load bench-test voltage/current limits and cranking-voltage checks.
Applies to
- NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1990 Mazda MX-5 Miata Workshop Manual; 1992 Mazda MX-5 Miata Workshop Manual
Sources (3)
View 3 source citations
Page TD–7 (PDF p.793) · Printed value & notes
Part no. 1193-10-89CPage TD–7 (PDF p.793)Printed: “Starter Type Conventional Output V·kW 12-0.95 (Others)”Page G–3 (PDF p. 287) · Printed value & notes
Part no. 1193-10-89CPage G–3 (PDF p. 287)Printed: “Starter Type Conventional Output V·kW 12-0.95”Visually checked against the original 1990 factory page, including printed units and component/test context.- 1992 Mazda MX-5 Miata Workshop ManualTier 1
Page TD–7 (PDF p. 1049) · Printed value & notes
Part no. 1271-10-91G (9999-95-0428-92)Page TD–7 (PDF p. 1049)Printed: “Starter Type Direct Output V-kW 12-0.95”
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)