Oxygen-sensor voltage response (1992–1993)
Sudden speed increase: 0.5–1.0 V; sudden decrease: 0–0.4 V.Sudden speed increase: 0.5–1.0 V; sudden decrease: 0–0.4 V.
Warm the engine and idle it. Disconnect the oxygen sensor and connect a voltmeter from its signal terminal to ground. Run at 3,000 rpm until the meter indicates approximately 0.55 V, then suddenly increase and decrease engine speed several times and compare the responses. Replace the sensor if incorrect. After inspection turn ignition OFF and disconnect the negative battery terminal for at least 20 seconds to clear the test-induced malfunction code; obtain the radio code and deactivate the factory audio anti-theft system before disconnecting the battery.
- NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
- Verified in: 1992 Mazda MX-5 Miata Workshop Manual
Sources (1)
View 1 source citations
- 1992 Mazda MX-5 Miata Workshop ManualTier 1
Page F–139 (PDF p. 293) · Printed value & notes
Part no. 1271-10-91G (9999-95-0428-92)Page F–139 (PDF p. 293)Printed: “3,000 rpm approx. 0.55V 0.5V—1.0V 0V—0.4V”
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)