Starter insulated-brush holder continuity check (2001–2003)
Removed starter brush-holder assembly: no continuity between each insulated brush and the holder plate.Removed starter brush-holder assembly: no continuity between each insulated brush and the holder plate.
Perform the factory starter inner-parts inspection with the starter disconnected from all power and the brush-holder assembly removed. Use an ohmmeter from each insulated brush to the metal holder plate. This requirement applies to the insulated brushes; do not interpret an intentionally grounded brush as an insulation failure. Replace the brush holder if an insulated brush has continuity to the plate. No numerical resistance or test-voltage threshold is printed.
- NB 2003 (BP-Z3)
- NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
- Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)
Sources (2)
View 2 source citations
- Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
Page 01–19–6 (PDF p. 360) · Printed value & notes
Part no. 1719-1U-01GPage 01–19–6 (PDF p. 360)Printed: “Verify that there is no continuity between each insulated brush and the plate using an ohmmeter.”Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned. - 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Starter Inner Parts Inspection (PDF p. 805) · Printed value & notes
Page Starter Inner Parts Inspection (PDF p. 805)Printed: “Verify that there is no continuity between each insulated brush and the plate using an ohmmeter.”
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)