Updated specs are available.
Starter commutator diameter grind limit (1990–1993)
This spec doesn't apply to the car you selected.
Not yet checked against the factory manual for your car's year. It's verified in the 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual; later manuals may differ.
1.21 in (30.8 mm)30.8 mm (1.21 in)
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure
Measure outer diameter across the commutator contact surface. Replace the armature when diameter is at this grind limit or less. If the surface is dirty, clean with cloth; if rough, repair using a lathe or fine sandpaper subject to the diameter limit.
Applies to
- NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page G–27 (PDF p. 311) · Printed value & notes
Part no. 1193-10-89CPage G–27 (PDF p. 311)Printed: “Grind limit: 30.8mm (1.21 in)”Visually checked against the original 1990 factory page, including printed units and component/test context.- 1992 Mazda MX-5 Miata Workshop ManualTier 1
Page G–25 (PDF p. 321) · Printed value & notes
Part no. 1271-10-91G (9999-95-0428-92)Page G–25 (PDF p. 321)Printed: “Grind limit: 30.8mm (1.21 in)”
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)