Updated specs are available.
Starter commutator runout (1990–1993)
This spec doesn't apply to the car you selected.
Not yet checked against the factory manual for your car's year. It's verified in the 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual; later manuals may differ.
0.001 in (0.03 mm)0.03 mm (0.001 in)
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure
Place the removed armature shaft on V-blocks and measure radial runout at the commutator with a dial gauge while rotating the armature. Factory text gives this runout value and directs lathe repair for small runout or armature replacement as necessary. Do not substitute the later NB maximum.
Applies to
- NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
- NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.
- Verified in: 1992 Mazda MX-5 Miata Workshop Manual; 1990 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page G–27 (PDF p. 311) · Printed value & notes
Part no. 1193-10-89CPage G–27 (PDF p. 311)Printed: “Runout: 0.03mm (0.001 in)”Visually checked against the original 1990 factory page, including printed units and component/test context.- 1992 Mazda MX-5 Miata Workshop ManualTier 1
Page G–25 (PDF p. 321) · Printed value & notes
Part no. 1271-10-91G (9999-95-0428-92)Page G–25 (PDF p. 321)Printed: “Runout: 0.03mm (0.001 in)”
Related service specs
- Ignition coil case insulation resistance (1990–1993)
- Ignition coil secondary winding resistance (2001–2004)
- Throttle-sensor idle/full-throttle switches and adjustment (1992–1993 5MT)
- Factory high-tension lead resistance per length (1990–1993)
- Starter control circuit diagnostic voltage (1992–1993)
- Factory S46A24LS battery charging-current limits (1990–1993)
- HEAD fuse rating — main fuse block (1990–1993)
- INJ fuse rating — main fuse block (1990–1993)