Automatic selected-range downshift reference (1999–2000)
Range2, all throttle positions, 2₃→2₂:101–107 km/h {63–66 mph}; A OFF→ON, B ON. Range1, all throttle positions, 1₂→1₁:35–41 km/h {22–25 mph}; A ON, B ON→OFF.Range2, all throttle positions, 2₃→2₂:101–107 km/h {63–66 mph}; A OFF→ON, B ON. Range1, all throttle positions, 1₂→1₁:35–41 km/h {22–25 mph}; A ON, B ON→OFF.
Perform factory road-test preparation: inspect coolant, engine oil, ATF level, ignition timing and idle speed. These are vehicle speeds in km/h with factory mph in braces, not engine rpm. Retain each specified throttle opening, selector range and O/D mode; do not interpolate other throttle settings. Solenoid A/B values describe stabilized states before and after a shift; momentary ON/OFF oscillation during a shift is normal per the source note. Follow the complete road-test procedure rather than treating a single speed or electrical state as proof of a defective part. For range2 or1 select that range, accelerate at half and wide throttle as directed and verify the printed downshift. Subscripts identify gear within the selected range, not decimal ratios. Keep the two selector-range tests distinct from D and O/D OFF.
- NB 1999–2000 (BP-4W, 4AT) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
- Verified in: 1999 Mazda MX-5 Miata Workshop Manual
Sources (1)
View 1 source citations
Page 05–13–4–6 (PDF pp. 481–483) · Printed value & notes
Page 05–13–4–6 (PDF pp. 481–483)Printed: “Vehicle speed at shift point table Range 2 All position 2₃→2₂ 101—107 {63—66} OFF→ON ON Range 1 All position 1₂→1₁ 35—41 {22—25} ON ON→OFF”
Related service specs
- Automatic TCM range-input voltage reference (1999–2000)
- Automatic TCM overdrive switch and lamp voltage reference (1999–2000)
- Automatic TCM throttle voltage reference (1999–2000)
- Automatic TCM speed-signal voltage reference (1999–2000)
- Automatic TCM engine-speed input voltage reference (1999–2000)
- Automatic TCM shift and lockup solenoid output voltage reference (1999–2000)
- Automatic TCM power and ground voltage reference (1999–2000)
- Automatic TCM serial communication diagnostic limitation (1999–2000)